Tag identifier
CONTROL continued
Commissioning Manual
01/2017
Meaning
Attributes:
font
•
The attribute defines the font size used.
–
0
–
1
–
2
–
3
–
4
–
5
color_bk
•
The attribute sets the background color of the control.
color_fg
•
The attribute sets the foreground color of the control.
Color coding (see Section "Color coding (Page 323)")
display_format
•
The attribute defines the processing format of the specified variable. This attribute must
be used when accessing a PLC float variable, as the access is realized by reading a
double word.
The following data formats are permitted:
–
FLOAT
–
INT
–
DOUBLE
–
STRING
Assigning expressions (e.g. text or graphic element to be displayed) to a list box, graphics
box or combo box:
Syntax:
<ITEM>Expression</ITEM>
<ITEM value ="<Value>">Expression</ITEM>
333