Timing diagram
Local variable definition
Inputs
Name
Type
Tmax
WORD
C_time
WORD
M_time
WORD
T_polar
BOOL
T_key
BOOL
T_01 to T_06
BOOL
OVload
BOOL
Outputs
Name
Type
T_cw
BOOL
T_ccw
BOOL
T_LED
BOOL
ERR1
BOOL
ERR2
BOOL
ERR3
BOOL
ERR4
BOOL
ERR5
BOOL
ERR6
BOOL
Assigned global variables
T_cw_m
M156.0
T_ccw_m
M156.1
CcwDelay
M156.2
K_active
M156.3
Tpos_C
M156.4
Tp_eq_Tc
M156.5
Tp_eq_0
M156.6
T_P_INDX
MD160
T_CHL
M168.4
Tm1_FindT
T15
Commissioning Manual
01/2017
Description
Number of tool on the turret, only 4, 6 are permitted
Turret clamping delay time (unit: 0.1 s)
Monitor time for searching for a tool (unit: 0.1s)
Tool position signal: NC/NO
Manual tool change key
Tool position sensor (low active)
Turret motor overload (NC)
Description
Turret CW for tool change
Turret CCW for turret clamping
Turret change status display
Error1: no turret position signal available
Error2: programmed tool exceeds turret range
Error3: tool searching time monitor time out
Error4: turret overload
Error5: max tool number setting error
Reserved
Position marking for turret CW rotation
Position marking for turret CCW rotation
Turret CCW rotation delay
Manual key active
Turret position changed
Programmed tool number equal to the current tool number
Programmed tool number equal to zero
Monitoring the tool change buffer zone in JOG mode
Operating mode locked
Monitoring timer for tool searching
187