Note
Use only shielded twisted pair cables; You must connect the cable shield to the metal or metalized connector casing of the
control system.
4.2.16

USB interface - X30

There is a USB interface on the back of the PPU. This USB interface is used for connecting with the MCP.
Pin assignment
Type
USB socket, type A Combicon 4-pin
Cable
Type: USB cable (0.5 m)
Illustration
Pin
1
2
3
4
Commissioning Manual
01/2017
Pin
Signal name
Signal name
Signal type
P5_USB0
VO
DM_USB0
I/O
DP_USB0
I/O
M
VO
Signal type
Comment
Comment
5 V power supply
USB data-
USB data+
Ground