Options - Siemens SINUMERIK 808D ADVANCED Commissioning Manual

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

Recommended connectors for 1PH1 motor power cables
Power cable
Motor side
Cross-
Supplier Article
section
4 × 2.5 mm
KST
2
KST
-
4 × 4 mm
KST
2
KST
-
4 × 10 mm
KST
2
KST
-
4 × 16 mm
KST
2
KST
-
2.1.1.5

Options

External 24 VDC power supply
A 24 VDC power supply is used to supply the 808D ADVANCED and V70 servo drive. Consider the following technical
specification requirements when selecting a 24 VDC power supply:
● 24 VDC supplying the SINUMERIK 808D ADVANCED:
Rated input voltage: 24 V
Max. input voltage: 28.8 V
Min. input voltage without output derating: 20.4 V
Rated input current: 2.25 A
● 24 VDC supplying the SINAMICS V70 drive:
Without a holding brake
Rated voltage (V)
24 (-15% to +20%)
The minimum voltage of 24 VDC -10% must be available at the connector on the motor side in order to guarantee
1)
that the brake reliably opens. If the maximum voltage of 24 VDC +10% is exceeded, then the brake could re-close.
The voltage drop along the brake feeder cable must be taken into consideration. The voltage drop ΔU for copper ca-
bles can be approximately calculated as follows:
ΔU [V] = 0.042 ∙ (l/q) ∙ I
Where: l = Cable length [m], q = Brake core cross section [mm
Commissioning Manual
01/2017
Picture
Quantity
number
(pieces)
RNYL 2-5
3
RNYL 2-6
1
-
-
-
RNYL 5-5
3
RNY 5-6
1
-
-
-
TLK 10-5
3
TLK 10-6
1
-
-
-
TLK 16-5
3
TLK 16-6
1
-
-
-
Maximum current (A)
1
Brake
Drive side
Used for
Sup-
Article
plier
number
U/V/W
KST
SNYL2-
4
PE
KST
RNYL 2-
5
-
IDEAL 6204
U/V/W
KST
SNYL5-
5
PE
KST
RNY 5-5
-
IDEAL 6204
U/V/W
KST
TLK 10-
5
PE
-
-
-
IDEAL 62P08
U/V/W
KST
TLK 16-
5
PE
-
-
-
IDEAL 62P08
With a holding brake
Rated voltage (V)
24 (-10% to +10%)
1)
], I
= DC current of brake [A]
2
Brake
Picture
Quantity
Used for
(pieces)
3
U/V/W
1
PE
1
Cable
shielding
3
U/V/W
1
PE
1
Cable
shielding
4
U/V/W/PE
-
-
-
1
Cable
shielding
4
U/V/W/PE
-
-
-
1
Cable
shielding
Maximum current (A)
3
29

Advertisement

Table of Contents
loading

Table of Contents