Siemens SINUMERIK 808D ADVANCED Commissioning Manual page 387

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

Frame size
Overload capability
Control system
Braking resistor
Protective functions
Cooling method
Environmental
Surrounding air
conditions
temperature
Ambient humidi-
ty
Operating environment
Altitude
Degree of protection
Degree of pollution
Commissioning Manual
01/2017
FSB
Note:
The overload capability is 150% by default. It can be set up to
200% via p0640, but the corresponding overload duration might
be reduced under the circumstances.
Servo control
External
Earthing fault protection, output short-cut protection, overvolt-
age/undervoltage protection
ture protection
Fan-cooled
Operation
0 °C to 45 °C: without power derating
45 °C to 55 °C: with power derating
Storage
-40 °C to +70 °C
Operation
< 90% (non-condensing)
Storage
90% (non-condensing)
Indoor (without direct sunlight), free from corrosive gas, combus-
tible gas, oil gas, or dust
< 1000 m (without derating)
IP20
Class 2
FSC
, I
t detection, IGBT overtempera-
2)
2
FSD
387