Cut-out dimensions and mounting clearance

Note
Make sure there is enough space around the PPU and the MCP for tightening the screws in the control cabinet.
Horizontal PPU and MCP (unit: mm)
Note
The illustration below uses PPU141.2 and the horizontal MCP with a reserved slot for the handwheel as an example.
All horizontal PPU/MCP versions share the same requirements for cut-out dimensions and mounting clearance.
* Note that PPU161.3 has no maintenance door but a slot for the system CF card.
To make maintenance easy, keep sufficient clearance (≥ 80 mm) between the maintenance door/system CF card slot and
the cabinet wall. The recommended depth of the cabinet is greater than 155 mm.
Vertical PPU and MCP (unit: mm)
Note
All vertical MCP versions share the same requirements for cut-out dimensions and mounting clearance. The illustration
below uses the vertical MCP with a reserved slot for the handwheel as an example.
Commissioning Manual
58
01/2017