Siemens SINUMERIK 808D ADVANCED Commissioning Manual page 429

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

Par. No.
Name
P43
Brake close speed while
motor operation
When motor speed exceeds 30 rpm and the drive generates an alarm, if, within the specified brake close time
(P42), the actual motor speed becomes smaller than the P43 setpoint, brake is closed when the actual speed
reaches the speed P43 sets.
P44
Drive enable time after the
brake close
When motor speed is lower than 30 rpm, the drive remains enabled within the time period set by P44 after
brake close.
P46
JOG speed
This parameter specifies the motor speed in JOG mode.
P47
Ramp-up/-down time con-
stant
This parameter defines the time period when the motor ramps up from 0 rpm to 2,000 rpm or ramps down from
2, 000 rpm to 0 rpm in JOG mode.
P99
Reserved for Siemens internal use only
Note
For parameters with an asterisk (*), the values in brackets are the second default values. For details, see Section "Function
menu".
Display data (read-only)
Data
Name
no.
D10
Torque setpoint
1)
D11
Actual value of the
1)
torque
D12
Actual value of the
1)
phase current
D20
Motor speed setpoint
D21
Actual motor speed
D30
Position revolution set-
point
D31
Position angle setpoint
D32
Actual position revolu-
tions
D33
Actual position angle
D34
Position deviation angle
D50
Digital input signal
2)
Commissioning Manual
01/2017
Range
Default
20-2000
100
20-2000
600
0-2000
200
0.0 –
4.0
10.0
Data
Unit
format
Decimal
Nm
Nm
A
Integer
RPM
RPM
Motor revo-
lutions
Increments
(10000/r)
Motor revo-
lutions
Increments
(10000/r)
Increments
(10000/r)
Bit
Bits in hex
Increment
20
10
10
0.1
Data
Display example
group
Current
Speed
-
Position -
I/O
Unit
Effective
r/min
Power on
ms
Power on
rpm
Immediately
s
Power on
429

Advertisement

Table of Contents
loading

Table of Contents