You can use the BOP for following operations:
● Standalone commissioning
● Diagnosis
● Parameter access
● Parameter settings
● SD card operation
● Drive restart
Button functions
Button
Description
M button
OK button
UP button
DOWN button
SHIFT button
Button combinations
Press this button combination for four seconds to restart the drive.
Moves the current display to the left page when
Moves the current display to the right page when
ple
460
Remarks
Exits from current menu
•
Switches between operating modes in the top level menu
•
Short-pressing:
Confirms selection or input
•
Enters sub menu
•
Acknowledges faults
•
Long-pressing:
Activates auxiliary functions
Sets Drive Bus address
•
Jog
•
Saves parameter set in drive (RAM to ROM)
•
Sets parameter set to default
•
Transfers data (drive to SD card)
•
Transfers data (SD card to drive)
•
Updates firmware
•
Navigates to next item
•
Increases a value
•
JOG in CW (clockwise)
•
Navigates to previous item
•
Decreases a value
•
JOG in CCW (counter-clockwise)
•
Moves the cursor from digit to digit for single digit editing, including the digit of
positive/negative signs
.
.
is displayed at the upper right corner, for example
is displayed at the lower right corner, for exam-