Installation
Metal clamp
Slot
Mainboard
Fig. 23
Fitting an interface card
Notes
– The ODAB options card must be fitted to slot IC2 (Mitel 415) or slot IC4 (Mitel 430) if it is to
be used for connecting a door intercom (see "Equipment on the ODAB options card",
page 138).
– The interface cards EAD4V and EAD4C cannot be fitted to slot IC4 of an Mitel 430 due to
their mechanical dimensions.
4. 5. 2

Wiring Adapter

Wiring adapters are used to route the interfaces of the interface cards to the RJ45
sockets on the front panel and are fitted to slots WA1...WA4. The WA0 slot is never
equipped. Slots WA3 and WA4 are to be found only on the Mitel 430 (see also Fig. 7).
The table below provides an overview of the combinations of wiring adapters and inter-
face cards. Unless specified otherwise, the corresponding wiring adapter is included in
the equipment supplied with each interface card.
Tab. 36
Combinations of wiring adapters / interface cards
Wiring Adapter
WA-TS0
98
Interface card
1
50 - 60°
Plug-in ori-
Interface card
entation
TIC-4TS
TTTT
TIC-4TS
STTT
TIC-2TS
TTTT
TIC-2TS
STTT
1)2)
ESST
STTT
Port number
X.1
X.2
T
T
S
T
T
T
S
T
S
T
syd-0580/1.2 – R4.1 – 08.2016
2
25°
X.3
X.4
T
T
T
T
Mitel 415/430 as of R4.1

Hide quick links: