Installation
To mount the communication server to the wall, proceed as follows:
1. Using the drill template or the instructions on the drill plan to mark out the three drill
holes. Make sure you observe the minimum distances to other objects, walls or ceil-
ings as shown in Fig. 12 and Fig. 13.
2. Drill the three dowel holes.
3. Insert the dowel plugs.
4. Screw in the two shorter upper dowel screws (position A or B). Observe the distance
between the screw heads and the wall as shown in Fig. 14.
5. Shut down the communication server (see "Shutdown Mode", page 206) and dis-
connect it from the power supply.
Warning
Be sure to observe the "Safety regulations", page 84.
6. Remove the housing cover.
7. Connect the earthing (see "Connecting the earthing wire", page 93).
8. Suspend the housing of the communication server onto the screws.
9. To secure the communication server screw in the long lower dowel screw (position
C).
10.Fit the housing cover.
11.Secure the snap-on tag to the front panel or to a suitable position on the housing
cover. The holes in the housing cover are spaced in such a way that the snap-on tag
can be secured both lengthways and crossways.
12.Reconnect the communication server to the power supply.
4. 2. 6

Desktop installation

To protect the cable connections the communication server can also be secured using
three screws. The same drilling plan (see Fig. 14) and the same procedure apply as for
wall mounting (see "Wall-mounting procedure", page 87).
Warning
To ensure adequate heat dissipation make sure that no objects are placed on top of the commu-
nication server (see also "Location requirements", page 83). Minimum distances must also be
observed as shown in Fig. 12.