6. 4. 3. 5

Boot Command Mode

The Boot Command Mode is used to carry out a first start or set a fixed IP address.
The Boot Command Mode is indicated by the SYS-LED flashing orange-red.
The Boot Command Mode is entered by pressing and holding down the control key
(LC) during the start-up state (see pattern[5], Tab. 92). Pattern[18] is displayed once
the Boot Command Mode has been entered.
Tab. 96
Patterns after entering the Boot Command Mode
Pat-
tern
F0
F1
No.
[18]
R
The Boot Command Mode is exited automatically if no input is made within 20 sec-
onds; the system returns to Startup Mode and restarts.
6. 4. 3. 6

Wiring Adapter Malfunction Mode

The system switches to this mode if an unsuitable wiring adapter is fitted into one of
the wiring adapter slots. Missing wiring adapters are also indicated.
The Wiring Adapter Malfunction Mode is indicated by one or more red flashing LEDs
F1...F4. The LED number corresponds to the number of the Wiring Adapter slot con-
cerned. The SYS-LED flashes green as in the Normal Mode.
Tab. 97
Sample pattern for Wiring Adapter Malfunction Mode
Pattern
F0
F1
No.
[20]
6. 4. 3. 7

Warning Mode

The system switches to the Warning Mode if a problem occurs that impairs the sys-
tem's normal operation. The Warning Mode is indicated by the red-green flashing SYS-
LED and is exited only once the problem is remedied.
The different warnings are binary coded and are indicated by the LEDs (F0...F4).
Mitel 415/430 as of R4.1
syd-0580/1.2 – R4.1 – 08.2016
F2
F3
F4
F2
F3
F4
R
Operation and Maintenance
SYS
Meaning
Boot Command Mode active
O R
SYS
Meaning
Wrong or missing wiring adapter in slot WA2
G