Mitel 430 System Manual page 146

Hide thumbs Also See for 430:
Table of Contents

Advertisement

Installation
Note:
DHCP is deactivated only temporarily and is reactivated after a subsequent restart.
Cable types
The Ethernet switch on the communications server features Auto MDI/MDIX. With the
automatic detection straight or crossover LAN cables can be used for all connection
types.
Configuration
The Ethernet interfaces routed to the front panel can be configured individually in the
IP addressing
(
=9g) view. In addition to Auto modes, manual settings are also possi-
ble for
Speed
and
MDI
Status LED
The status of the Ethernet interface LAN1 is indicated on the LED display panel (see
"LED display", page 200).
Cable Requirements
Use commercial Cat. 5 cable, or choose a cable type with the following characteristics:
Tab. 75
Requirements for an Ethernet cable
Core pairs × cores
Stranded
Wire diameter, core
Screening
Category
See also:
For more information about the Ethernet interface on the application card, see the CPU2-S
application card installation manual.
146
type.
2 × 2 (short distances also 1 × 4)
yes
0.4...0.6 mm
yes
Cat. 5 minimum
Mitel 415/430 as of R4.1
syd-0580/1.2 – R4.1 – 08.2016