Operation and Maintenance
Event message
Overheat
(Mitel 470 only)
Overload detected on USB
port (CPU2)
(Mitel 470 only)
Port out of service
QSIG licence limit reached
Radio unit port active
Register error
Remote maintenance disa-
bled
222
Trigger condition
The temperature inside the communication
server is too high. Appropriate measures must
be taken immediately to improve heat dissipa-
tion. Measures are automatically adopted,
depending on where the overheating occurs:
FXO and FXS interface card:
• the ports are deactivated in groups of 4 ports.
• Once they have cooled down below a defined
card-specific value, the ports are automatically
reactivated group by group.
CPU2 applications card
• The card will be completely deactivated. Once
it has cooled down below a defined value, the
card is automatically reactivated.
Internal power supply unit PSU2U or call man-
ager card CPU1:
• the communication server will be shut down
completely.
Notes:
• To prevent the system from overheating, no
more than 30% of the FXS ports should be
active simultaneously per 32FXS card and no
more than 50 FXS ports per system.
• PRI, BRI and DSI cards do not have tempera-
ture sensors and are therefore never deacti-
vated due to overheating.
A (current) overload was detected on one of the
USB interfaces on the applications card (CPU2).
Note: The maximum current input at the USB
interfaces varies:
A port previously in operation has stopped func-
tioning.
Maximum number of licensed outgoing connec-
tions with QSIG protocol exceeded
The radio unit is responding again
• Card not fitted
• Card not logged on
• Card defective
Remote maintenance has been deactivated
1)
Details
Severity
Card number, tem-
critical
perature, date, time
(negative,
with
match)
Date, time
Normal
(without
match)
Number of the slot,
Normal
relevant port number,
(without
date, time
match)
Route number, user
Normal
number, date, time
(without
match)
Card number, port
Serious
number, date, time
(positive,
with
match)
Card number, date,
Normal
time
(without
match)
Date, time
Normal
(positive,
with
match)