Tab. 55
S bus configurations depending on line length and the number of terminals.
S bus
Length (max.)
Server ↔ terminal
Terminal 1 ↔ Terminal 4
Number of terminals (max.)
Note
The maximum number of terminals per S bus depends on the power requirements of the termi-
nals (see "Restrictions", page 124).
Communica-
tion server
Fig. 46
S bus, short
2 x 100
Fig. 47
S bus, short, V-shaped
Communica-
tion server
Fig. 48
S bus, long
Mitel 415/430 as of R4.1
syd-0580/1.2 – R4.1 – 08.2016
Short
150 m
8
1.
1.
2.
3.
Ω
max. 150 m
Short, V-shaped
Long
2 × 150 m
500 m
20 m
8
4
2.
3.
max. 150 m
Communication
server
(Main)
distribution
8. Connec-
frame
tion point
max. 150 m
1.
2.
max. 20 m
max. 500 m
Installation
Point-to-point
1'000 m
1
8. Connection
point
2 x 100
Ω
2 x 100
Ω
4. Connection
point
2 x 100
Ω
123