Operation and Maintenance
6. 4. 4. 7

Resetting the IP address

The IP address data is stored on the EIM card and is retained even after a first start.
The following sequence only resets the IP address data of the communication server to
the default values. All the other data is retained.
Requirement:
The system is in "Boot Command Mode", page 205.
1. Press the pilot key several times with a short keypress (SC) until "F2" lights up red.
2. Press the pilot key with a long keypress (LC)
→ After 2 second keypress "F2" lights up green by way of confirmation.
→ The IP address data is reset to the default values once the key is released. The
startup then continues normally.
Default values of the IP address data:
• IP address: 192.168.104.13
• Subnet mask: 255.255.255.0
• Gateway: 0.0.0.0
6. 4. 4. 8

Thorough RAM test

To carry out a thorough RAM test during startup, press the pilot key briefly (SC) during
the orange LED test (pattern[2]). The thorough RAM test lasts for approx. 2 minutes
and is displayed with Pattern [4]. The startup then continues normally.
6. 4. 4. 9

Emergency Upload via LAN

An Emergency Upload is required whenever there is no longer any executable system
software stored on the communication server for whatever reason or if a downgrade to
an older software version is to be carried out.
For this, proceed as described in "Loading new or older system software with System
Search", page 186.