Operation and Maintenance
– Never disconnect the communication server from the power supply during the update pro-
cess. This may prevent executable system software from being available on the communi-
cation server, and make an EUL (Emergency Upload) necessary.
See also:
A detailed description of the software upload procedure with WebAdmin is available in the
online help.
Loading new or older system software with System Search
Whenever a standard software upload is not possible, has proved faulty, or to replace a
Flash card or if you wish to load an earlier system software (Downgrade), you must
carry out a Emergency Upload. You need the search and help tool System Search.
Note:
A first start of the communication server is also performed with an Emergency Upload. All the
already stored configuration data is deleted and replaced with the default values of the sales
channel. Therefore, before an Emergency Upload back up your configuration data (if still possi-
ble).
To perform an Emergency Upload, proceed as follows:
1. Set the communication server to boot mode using the control key (see "Boot Mode",
page 206).
2. Start System Search and select
3. Enter the communication server IP address.
4. Select the system software package to be uploaded (zip file).
5. Click the
Upload
→ Emergency Upload is started.
Note:
During an Emergency Upload the communication pattern for the start-up state is displayed for a
long time (up to 10 minutes) (Pattern [5], Tab. 92). This is normal since it takes a while to
decompress the system software..
6. 2. 2

Firmware for corded system phones

The communication server's software package contains the software for certain system
phones (DSI and IP), which is updated in each case along with the system software.
For other system phones (SIP) the firmware is located on a firmware server.
The Office 10, Office 25 and MiVoice 5360 system phones do not have their own mem-
ory. All other system phones have a Flash memory.
SIP system phones
The firmware for Mitel 6700 SIP / 6800 SIP series SIP phones as well as for Mitel
BluStar 8000i, Mitel BluStar clients and Mitel Dialer is preferably located on a firmware
186
Emergency
button.
Upload.
syd-0580/1.2 – R4.1 – 08.2016