6. 4. 4

Carrying out functions

The pilot key is used to carry out various functions. For certain functions the system
has to be in a particular operating state beforehand.
6. 4. 4. 1

Shutting down the communication server

The communication server can be shut down in a controlled manner. It then remains in
Shutdown Mode (see "Shutdown Mode", page 206) for three minutes before it starts
again automatically. Within these three minutes, the communication server can be dis-
connected from the power supply.
Requirement:
The system is in "Application Command Mode", page 204.
1. Press the pilot key with a short keypress (SC) until "F1" lights up.
2. Press the pilot key with a long keypress (LC)
→ After 2 second keypress "F1" lights up green by way of confirmation.
→ After the key is released the communication server is shut down and displays
Pattern [22] for three minutes.
Tip:
You can also shut down the communication server in a controlled manner via WebAdmin in the
Maintenance
/
6. 4. 4. 2

Normal restart with database backup

The following sequence carries out a database backup and saves the data on the com-
munication server's internal file system. The communication server is then restarted
automatically:
Requirement:
The system is in "Application Command Mode", page 204.
1. Press the pilot key several times with a short keypress (SC) until "F2" lights up.
2. Press the pilot key with a long keypress (LC)
→ After 2 second keypress "F2" lights up green by way of confirmation.
→ Once the key is released, a database backup is carried out followed by a commu-
nication server restart.
Tip:
You can also restart the communication server via WebAdmin in the
reset
(
=4e) view.
Mitel 415/430 as of R4.1
syd-0580/1.2 – R4.1 – 08.2016
System reset
(
=4e) view.