Analogue network interfaces
• Voice path with A/D and D/A conversion (standard PCM, A-law)
• Transmission as per ES 201 168 (level country-specific)
• Signalling as per TBR 21
• Pulse or DTMF dialling, Flash signal
• Loop current detection
• Call charge receive 12 or 16 kHz (frequency and level setting country-specific)
• CLIP detection in accordance with ETS 300 778-1
7. 4. 2

Terminal interfaces

The following technical data applies to the terminal interfaces:
Digital terminal interface DSI
• Proprietary interface, two-wire
• Two system phones of the MiVoice 5300 series can be connected per interface
1)
(AD2 protocol)
• One SB-4+/SB-8 radio unit can be connected (with 8 channels the SB-8 radio units
requires two DSI interfaces)
• Power supply min. 75 mA, limiting at approx. 80 mA, terminal voltage 36...48 V
• Line termination in the phone
• Transparent transmission of 2 PCM channels
Digital terminal interface BRI-S
• Standard Euro ISDN interface
• Phantom power supply min. 140 mA, limiting at approx. 170 mA, terminal voltage
36...41 V
• Up to 8 terminals can be connected
• Maximum of 2 simultaneous call connections
Analogue terminal interface FXS
• Configurable multifunctional interface for connecting analogue terminals and equip-
ment.
• The following applies for the FXS mode
bell:
1) Office 10, Office 25, Office 35, Office 45/45pro are supported as before
Mitel 415/430 as of R4.1
syd-0580/1.2 – R4.1 – 08.2016
Phone /
Fax,
two-wire door
Annex
and
general
247