Mitel 430 System Manual page 116

Hide thumbs Also See for 430:
Table of Contents

Advertisement

Installation
Tab. 51
DSI-AD2 bus length and number of phones
Number of phones
Total length of DSI-AD2 bus
1
A: max. 1200 m
2
B: max. 1200 m
Communica-
tion server
Communica-
tion server
Fig. 42
DSI-AD2 bus
Notes
The total length of the cables from the communication server to the system phone must not be
less than 10 m.
Restrictions
The maximum length of an DSI-AD2 bus is further restricted by:
• the maximum power requirements of the connected system phones and their sup-
plementary equipment. In this context the SB-4+ and SB-8 DECT radio units are
also considered as system phones.
• the line resistance (depending on the line length and wire diameter)
Tab. 52
Maximum power requirements of the system phones on the DSI bus
1)
System phone
2)
MiVoice 5360
MiVoice 5361
MiVoice 5370
MiVoice 5380
MiVoice 5370, MiVoice 5380 with power supply unit
Expansion key module MiVoice M530
Expansion key module MiVoice M530
116
Distance between the 1st and 2nd ones Connec-
tion point (without connection cable)
C: max. 10 m
A
1. Connection
point
B
Socket
DSI-AD2 interface
DSI-AD2 interface
DSI-AD2 interface
DSI-AD2 interface
DSI-AD2 interface
MiVoice 5370
MiVoice 5380
1. Connection
point
2. Connection
point
C
Max. power input
[mW]
900
3)
1220
3)
1220
3)
1340
0
300
500
Mitel 415/430 as of R4.1
syd-0580/1.2 – R4.1 – 08.2016

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

415Mivoice office 400

Table of Contents