Ethernet Interfaces - Mitel 430 System Manual

Hide thumbs Also See for 430:
Table of Contents

Advertisement

Installation
Fig. 66
Audio interface
Tab. 72
Technical data of the audio interface
Input impedance
Input level
Input circuit
Output resistance audio source
Installation cable
Socket
Circuit type
4. 7. 7

Ethernet interfaces

The Mitel 415/430 communication servers have a 10/100BaseT 2-port LAN switch.
The Ethernet interfaces are permanently routed to the front panel and labelled accord-
ingly. The RJ45 sockets are highlighted in colour in the figure below.
Fig. 67
Connection possibilities for Ethernet interfaces
Note
Circuit type as per EN/IEC 60950: SELV
144
approx. 15 kΩ
0.1...5 V (configurable in 8 levels)
asymmetrical
< 1 kΩ
NF cable screened (required for low levels)
3.5 mm stereo jack
as per EN/IEC 60950: SELV
syd-0580/1.2 – R4.1 – 08.2016
Mitel 415/430 as of R4.1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

415Mivoice office 400

Table of Contents