Installation
Notes:
– The EFOP fan-out-panel is reset from emergency operation to normal operation with a delay
of 3 minutes. This allows the communication server to reboot after a power failure. The
delay also applies to individual FXS lines.
– If individual FXS lines are in emergency operation, the corresponding analogue exchange
line from the communication server can no longer be used. Unexpected faulty switching
may occur if an active call was being made on the FXS line and the exchange line prior to
the emergency operation.
– In emergency operation the emergency phone is connected directly with the analogue
exchange line so no exchange access prefix has to be dialled.
Connection
The EFOP fan-out-panel comprises 5 connection blocks of 10 RJ45 sockets each. The
line switchover is carried out on the two left-hand connection blocks. The three right-
hand connection blocks are used for separating the four-fold assigned RJ45 sockets
FXS1-4 and FXO1-4. The unassigned connection blocks can be used for other pur-
poses.
The diagram below shows the connection between an EFOP fan-out-panel and 4
emergency phones and 4 analogue exchange lines.
3
1
PSTN
1
3
1 PSTN 3
2
4
2 PSTN 4
4
PSTN
2
Fig. 60
Connection of EFOP fan-out-panel (example)
134
FXS 1-4
1
3
1 PSTN 3
1
2
3
4
FXO 1-4
2
4
2 PSTN 4
FXS 1-4
1
3
5
1
2
3
4
FXO 1-4
2
4
6
FXS
1...4
EFOP
7
1-4
1
3
8
5-8
2
4
FXO
1...4
Mitel 415/430 as of R4.1