Installation
4. 2. 4

Safety regulations

Be sure to observe the following safety regulations before carrying out work inside a
communication server:
Warning
Components, interface cards or system modules can be damaged by electrical voltage.
Always disconnect the communication server from the power supply before removing the hous-
ing cover.
Warning
Components can be damaged by electrostatic discharge when touched.
Always touch the earthed metal case of the communication server before carrying out work
inside the housing. This also applies to interface cards and system modules that are no longer
packed inside the ESD protective wrapping.
4. 2. 5

Wall mounting

There are two possibilities for wall mounting. In the first variant the front panel faces
right (see Fig. 12); in the second, it faces downwards (see Fig. 13). The wall-mounting
option chosen will depend on the way the cables are routed. The LED display remains
visible whatever the mounting position, even when the cable cover is fitted.
Warning
A wall-mounting option in which the front panel faces upwards or to the right is not permitted.
Inadequate heat dissipation can damage the communication server.
4. 2. 5. 1

Minimum distances

To ensure adequate heat dissipation, minimum distances need to be maintained with
other objects such as cable ducts, cabinets or mobile objects. Maintaining minimum
distances also allows the installation of the cable cover and the possibility of suspend-
ing the communication server into and out of the wall-mounted screws.
The two diagrams below illustrate the two wall-mounting possibilities.
84
Mitel 415/430 as of R4.1
syd-0580/1.2 – R4.1 – 08.2016