– If the defective EIM card was replaced by a new one, all DECT cordless phones must be
logged on again. This is necessary because the DECT identification numbers are stored on
the EIM card.
6. 3. 6

Mainboard

If the components on the mainboard are defective or permanently faulty, the entire
communication server with the metal chassis must be replaced.
To replace the communication server, proceed as follows:
Warning
Be sure to observe the "Safety regulations", page 84.
1. Back up the configuration data and audio data, if still possible.
2. Carry out preparations (see "Preparations", page 189).
3. Remove the housing cover.
4. Remove the interface cards (see "Interface cards", page 191), the system modules
(see "System modules", page 193) and the wiring adapter.
5. Change the EIM card of the defective mainboard to the new mainboard (see "Re-
placing the EIM card", page 194).
6. Dismantle all the connected cables in such a way that the new communication
server can be identically reconnected.
Note: The mainboard is not dismantled but replaced complete with metal housing.
7. The new communication server can now be reassembled, fitted and installed in the
reverse sequence.
8. Carry out a first start of the system (see "First start of the communication server",
page 178) and upload the configuration data from a backup file back on to the com-
munication server.
6. 3. 7

Replacing system terminals

6. 3. 7. 1

DSI system phones

Phones with the same level of added features
Replacing a defective phone
Once the defective DSI system phone has been replaced by an identical phone the ter-
minal configuration data is automatically transferred.
Mitel 415/430 as of R4.1
syd-0580/1.2 – R4.1 – 08.2016
Operation and Maintenance
195