Event message
External auxiliary power sup-
ply failed
(Mitel 470 only)
External auxiliary power sup-
ply in service
(Mitel 470 only)
External event message des-
tination not reachable
External event message des-
tination reachable
Fan failure
(Mitel 415/430
only)
Fan failure
(Mitel 470 only)
Fan in operation
(Mitel 415/430 only)
Fan in operation
(Mitel 470
only)
FIAS command buffer full
Mitel 415/430 as of R4.1
syd-0580/1.2 – R4.1 – 08.2016
Trigger condition
The external auxiliary power supply to the com-
munication server has failed. If the auxiliary
power supply unit has been used for redundant
operation, there are no short-term limitations. If
the auxiliary power supply unit has been used to
increase the power supply, the internal power
supply unit overflow must be calculated.
The external auxiliary power supply to the com-
munication server is working.
External signal destination not automatically
reachable
External signal destination is now reachable
The fan is jammed or defective or the connection
is no longer making contact.
• Parameter = 0: No more fans in operation.
→ Risk of overheating: Replace defective fan.
The fan is jammed or defective or the connection
is no longer making contact.
• Parameter = 0: No more fans in operation.
→ Risk of overheating: System shut down
after 2 minutes.
→ Replace defective fan.
• Parameter = 1: Only one fan left in operation.
→ System still running with only one fan.
→ Replace defective fan.
The fan is back in service again after a failure.
• Parameter = 0: Fan back in service again.
The fan is back in service again after a failure.
• Parameter = 0: A fan is back in service again.
• Parameter = 1: Second fan back in service
again.
The command buffer to the PMS interface is full. Date, time
Operation and Maintenance
1)
Details
Date, time
Date, time
Cause (0: Busy
/1: Not available
/2:(not used),
2: Barred /3: not
defined), date, time
Date, time
Parameter, date,
time
Parameter, date,
time
Parameter, date,
time
Parameter, date,
time
Severity
Normal
(negative,
with
match)
Normal
(positive,
with
match)
Serious
(negative,
with
match)
Serious
(positive,
with
match)
critical
(negative,
with
match)
critical
(negative,
with
match)
critical
(positive,
with
match)
critical
(positive,
with
match)
critical
(negative,
with
match)
217