Drive Watt Loss Data; Drive Watt Loss Data - YASKAWA L1000V Technical Manual

200/400 v classes: 4.0 to 15 kw
Hide thumbs Also See for L1000V:
Table of Contents

Advertisement

A.4 Drive Watt Loss Data
Model Number
CIMR-LC
2V0018
2V0025
2V0033
2V0047
2V0060
Model Number
CIMR-LC
4V0009
4V0015
4V0018
4V0024
4V0031
YASKAWA EUROPE SIEP
Table A.3 Watt Loss 200 V Class Three-Phase Models
Rated Amps (A)
Heatsink Loss (W)
17.5
25.0
33.0
47.0
60.0
Table A.4 Watt Loss 400 V Class Three-Phase Models
Rated Amps (A)
Heatsink Loss (W)
9.2
14.8
18.0
24.0
31.0
YASKAWA AC Drive L1000V Technical Manual
Carrier Frequency 8kHz
Interior Unit Loss (W)
110.5
43.3
213.3
68.1
239.5
79.6
347.6
113.8
473.9
156.7
Carrier Frequency 8 kHz
Interior Unit Loss (W)
107.2
41.5
166.0
61.7
207.1
75.0
266.9
102.1
319.1
115.4
A.4 Drive Watt Loss Data
Total Loss (W)
153.8
281.4
319.1
461.4
630.6
Total Loss (W)
148.7
227.7
282.1
369.0
434.5
A