Fault Reset Methods - YASKAWA L1000V Technical Manual

200/400 v classes: 4.0 to 15 kw
Hide thumbs Also See for L1000V:
Table of Contents

Advertisement

6.8 Diagnosing and Resetting Faults
u Fault Reset Methods
When a fault occurs, the cause of the fault must be removed and the drive must be restarted. The table below lists the
different ways to restart the drive.
After the Fault Occurs
Fix the cause of the fault, restart the drive, and
reset the fault
Resetting via Fault Reset Digital Input
If the above methods do not reset the fault, turn off the drive main power supply. Reapply power after the digital
operator display is out.
Note: If the Up/Down command is present, the drive will disregard any attempts to reset the fault. Remove the Up/Down command
before attempting to clear a fault situation.
188
Procedure
Press
on the digital operator.
Close then open the fault signal digital input. Digital inputs
S3 through S7 can be configured as fault reset (H1-
YASKAWA EUROPE SIEP
YEG
RESET
Fault Reset Switch
=12).
2
1
YASKAWA AC Drive L1000V Technical Manual
STOP
Drive
S Fault Reset Digital Input
SC Digital Input Common
ON
OFF

Hide quick links: