i.2 General Safety
Observe proper electrostatic discharge procedures (ESD) when handling the drive, circuit boards, and option
cards.
Failure to comply may result in ESD damage to the drive circuitry.
Never connect or disconnect the motor from the drive while the drive is outputting voltage.
Improper equipment sequencing could result in damage to the drive.
Do not perform a withstand voltage test on any part of the drive.
Failure to comply could result in damage to the sensitive devices within the drive.
Do not operate damaged equipment.
Failure to comply could result in further damage to the equipment.
Do not connect or operate any equipment with visible damage or missing parts.
Install adequate branch circuit short circuit protection per applicable codes.
Failure to comply could result in damage to the drive.
The drive is suitable for circuits capable of delivering not more than 30,000 RMS symmetrical Amperes, 240 Vac
maximum (200 V Class) and 480 Vac maximum (400 V Class).
Do not use unshielded cable for control wiring.
Failure to comply may cause electrical interference resulting in poor system performance. Use shielded twisted-pair
wires and ground the shield to the ground terminal of the drive.
Do not allow unqualified personnel to use the product.
Failure to comply could result in damage to the drive or braking circuit.
Carefully review the braking option instruction manual when connecting a braking option to the drive.
Do not modify the drive circuitry.
Failure to comply could result in damage to the drive and will void warranty.
Yaskawa is not responsible for any modification of the product made by the user. This product must not be modified.
Failure to comply could result in damage to the drive or braking circuit.
Check all the wiring to ensure that all connections are correct after installing the drive and connecting other
devices.
Failure to comply could result in damage to the drive.
Do not connect unapproved LC or RC intereference suppression filters, capacitors, or overvoltage protection
devices to the output of the drive.
Using unapproved filters could result in damage to the drive or motor equipment.
Check the motor rotation and elevator movement direction prior to starting up the drive.
The drive puts out voltage in phase sequence U-V-W with an Up command. Make sure the elevator moves up if the
motor is supplied with this phase sequence.
Always remove the ropes when performing Rotational Auto-Tuning.
During Rotational Auto-Tuning the drive turns the motor for a certain time. Not removing the ropes might result in
damage to the equipment.