6.6

Auto-Tuning Fault Detection

When the Auto-Tuning faults shown below are detected, the fault is displayed on the digital operator and the motor
coasts to a stop. Auto-Tuning faults do not trigger a multi-function terminal set for fault or alarm output.
An End
error indicates that Auto-Tuning has successfully completed with discrepancies in the calculations. If an End
error occurs, check for the cause of the error using the table below, and perform Auto-Tuning again after fixing the
problem. Start the application if no problem can be diagnosed despite the existence of the End
An Er-
error indicates that Auto-Tuning has not successfully completed. If an Er-
the error using the table below, and perform Auto-Tuning again after fixing the problem.
u Auto-Tuning Codes, Causes, and Possible Solutions
Digital Operator Display
End1
Cause
The torque reference exceeded 20% during
Auto-Tuning.
The results from Auto-Tuning the no-load current
exceeded 80%.
Digital Operator Display
End2
Cause
Motor data entered during Auto-Tuning was
incorrect.
Results from Auto-Tuning are outside the parameter
setting range, assigning the iron-core saturation
coefficient (E2-07, E2-08) a temporary value.
Digital Operator Display
End3
Cause
The correct current rating printed on the nameplate
was not entered into T1-04.
Digital Operator Display
Er-01
Cause
Motor data or data entered during Auto-Tuning was
incorrect.
Motor output power and motor-rated current settings
(T1-02 and T1-04) do not match.
Motor rated current and detected no-load current are
not consistent with another.
Base frequency and motor rated speed (T1-05 and
T1-07) do not match.
Digital Operator Display
Er-02
Cause
An alarm was triggered during Auto-Tuning.
Digital Operator Display
Er-03
Cause
Auto-Tuning canceled by pressing STOP button.
Digital Operator Display
Er-04
Cause
Motor data entered during Auto-Tuning was
incorrect.
Results from Auto-Tuning are outside the parameter
setting range or the tuning process took too long.
Motor cable or cable connection faulty.
YASKAWA EUROPE SIEP
Table 6.10 Auto-Tuning Codes, Causes, and Possible Solutions
Excessive V/f Setting (detected only during Rotational Auto-Tuning, and displayed after Auto-Tuning is complete)
• Before Auto-Tuning the drive, verify the information written on the motor nameplate and enter that data to T1-03 through T1-05.
• Enter proper information to parameters T1-03 to T1-05 and repeat Auto-Tuning.
Motor Iron-Core Saturation Coefficient (detected only during Rotational Auto-Tuning and displayed after Auto-Tuning is complete)
• Make sure the data entered to the T1 parameters match the information written on the motor nameplate.
• Restart Auto-Tuning and enter the correct information.
Check and correct faulty motor wiring.
Rated Current Setting Alarm (displayed after Auto-Tuning is complete)
• Check the setting of parameter T1-04.
• Check the motor data and repeat Auto-Tuning.
Motor Data Error
• Check that the motor data entered to T1 parameters matches motor nameplate input before Auto-Tuning.
• Start Auto-Tuning over again and enter the correct information.
• Check the drive and motor capacities.
• Correct the settings of parameters T1-02 and T1-04.
• Check the motor rated current and no-load current.
• Correct the settings of parameters T1-04 and E2-03.
• Set T1-05 and T1-07 to the correct value.
• Check if the correct pole number was entered to T1-06.
Alarm
Exit the Auto-Tuning menu, check the alarm code, remove the alarm cause, and repeat Auto-Tuning.
STOP Button Input
Auto-Tuning did not complete properly and will have to be performed again.
Line-to-Line Resistance Error
• Make sure the data entered to the T1 parameters match the information written on the motor nameplate.
• Restart Auto-Tuning and enter the correct information.
Check and correct faulty motor wiring.
YASKAWA AC Drive L1000V Technical Manual

6.6 Auto-Tuning Fault Detection

error.
error occurs, check for the cause of
Error Name
Possible Solutions
Error Name
Possible Solutions
Error Name
Possible Solutions
Error Name
Possible Solutions
Error Name
Possible Solutions
Error Name
Possible Solutions
Error Name
Possible Solutions
6
183

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents