B.3 Parameter Table
No. (Addr.)
Name
U1-12
Drive Status
(4BH)
U1-16
Output Speed after Soft Start
(53H)
U1-18
oPE Fault Parameter
(61H)
U1-24
Input Pulse Monitor
(7DH)
U1-25
Software Number (Flash)
(4DH)
U1-26
Software No. (ROM)
(5BH)
<9> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.
<12> The display resolution depends on drive model (o2-04).
<31> Setting units are determined by the digital operator display unit selection (o1-03).
n
U2: Fault Trace
No. (Addr.)
Name
U2-01
Current Fault
(80H)
U2-02
Previous Fault
(81H)
U2-03
Speed Reference at Previous
(82H)
Fault
U2-04
Output Speed at Previous Fault
(83H)
U2-05
Output Current at Previous
(84H)
Fault
U2-06
Motor Speed at Previous Fault
(85H)
U2-07
Output Voltage at Previous
(86H)
Fault
U2-08
DC Bus Voltage at Previous
(87H)
Fault
U2-09
Output Power at Previous
(88H)
Fault
U2-10
Torque Reference at Previous
(89H)
Fault
U2-11
Input Terminal Status at
(8AH)
Previous Fault
U2-12
Output Terminal Status at
(8BH)
Previous Fault
244
All Modes
Verifies the drive operation status.
All Modes
Displays output speed with ramp time and jerk settings.
All Modes
Displays the parameter number that caused the oPE
All Modes
Displays the frequency of the signal at the pulse train input terminal.
All Modes
FLASH ID
All Modes
ROM ID
All Modes
Displays the current fault.
All Modes
Displays the previous fault.
All Modes
Displays the speed reference at the previous fault.
All Modes
Displays the output speed at the previous fault.
All Modes
Displays the output current at the previous fault.
V/f
OLV
Displays the motor speed at the previous fault.
All Modes
Displays the output voltage at the previous fault.
All Modes
Displays the DC bus voltage at the previous fault.
All Modes
Displays the output power at the previous fault.
V/f
OLV
Displays the torque reference at the previous fault.
All Modes
Displays the input terminal status at the previous fault. Displayed as in U1-10.
All Modes
Displays the output status at the previous fault. Displays the same status displayed in U1-11.
YASKAWA EUROPE SIEP
Description
During run
During zero-speed
During REV
During fault reset
signal input
During speed agree
Drive ready
During alarm
detection
During fault detection
or Err (EEPROM write error) error.
Description
OLV w PG
V/f w PG
Analog Output
Level
common_
TMonly
No signal output
available
common_
0.01 Hz
TMonly
10 V: Max frequency
common_
No signal output
TMonly
available
common_
No signal output
TMonly
available
common_
No signal output
TMonly
available
common_
No signal output
TMonly
available
Analog Output
Level
common_
No signal output
TMonly
available
common_
No signal output
TMonly
available
common_
No signal output
0.01 Hz
TMonly
available
common_
No signal output
0.01 Hz
TMonly
available
common_
No signal output
TMonly
0.01 A
available
No signal output
0.01 Hz
available
common_
No signal output
TMonly
0.1 Vac
available
common_
No signal output
TMonly
available
common_
No signal output
TMonly
0.1 kW
available
common_
No signal output
TMonly
available
common_
No signal output
TMonly
available
common_
No signal output
TMonly
available
YASKAWA AC Drive L1000V Technical Manual
Unit
Page
<31>
Unit
Page
<31>
<31>
<31>
1 Vdc
0.1%

Hide quick links:

Advertisement

Table of Contents
loading