YASKAWA L1000V Technical Manual page 257

200/400 v classes: 4.0 to 15 kw
Hide thumbs Also See for L1000V:
Table of Contents

Advertisement

n
EMC Filters
Install the drive with the EMC filters listed below to comply with the EN61800-3/EN12015 requirements.
Model
CIMR-LC
Type
2V0018
FS23637-24-07
2V0025
FS23637-52-07
2V0033
2V0047
FS23637-68-07
2V0060
FS23637-80-07
4V0009
FS23639-15-07
4V0015
FS23639-30-07
4V0018
4V0024
FS23639-50-07
4V0031
Figure C.5
n
AC Reactors for EN 12015 Compliance
For compliance with EN 12015 select an input reactor according to
Model
CIMR-LC
2V0018
2V0025
2V0033
2V0047
2V0060
4V0009
4V0015
4V0018
4V0024
4V0031
YASKAWA EUROPE SIEP
Table C.2 EN61800-3 Class C1 Filters
Filter Data (Manufacturer: Schaffner)
Weight
Rated Current (A)
Three-Phase 200 V Class
24
52
68
80
Three-Phase 400 V Class
15
30
50
W
A
Figure C.5 EMC Filter Dimensions
Table C.3 AC Reactor Selection for EN 12015 Compliance
Reactor Model (IP00)
Reactor Model (IP20)
Three-Phase 200 V Class
LR3 40-4/20
LR3 40-4/45
Available as option, same model as
IP00, plus IP20 request.
LR3 40-4/70
Three-Phase 400 V Class
B 0903084
B 0903085
B 0903086
B 0903087
YASKAWA AC Drive L1000V Technical Manual
Dimensions
[W x D x H]
(kg)
(mm)
144 × 174 × 50
0.9
137 × 304 × 56
2.0
175 × 340 × 65
2.6
212 × 393 × 65
3.1
144 × 174 × 50
0.9
137 × 304 × 56
1.8
175 × 340 × 65
2.7
H
Y
LINE
LOAD
PE
Table
C.3.
Reactor Data (Manufacturer: Block)
Inductance [mH]
B 0903088
B 0903089
B 0903090
B 0903091
C.2 European Standards
Drive
Y x X
Mounting
Screw A
120 × 161
M4
100 × 289
M5
130 × 325
M5
167 × 378
M6
120 × 161
M4
100 × 289
M5
130 × 325
M5
Nominal Current [A]
1.47
20
0.65
45
0.42
70
10.0
8
5.10
16
4.70
21
3.15
27
Filter
Mounting
Screw
M5
M5
M6
M8
M5
M5
M6
C
257

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents