o2: Digital Operator Keypad Functions
No. (Addr.)
Name
o2-01
LO/RE Key Function Selection
(505H)
o2-02
STOP Key Function Selection
(506H)
o2-03
User Parameter Default Value
(507H)
o2-04
(508H)
Drive Model Selection
<1>
o2-05
Speed Reference Setting Method
(509H)
Selection
o2-06
Operation Selection when Digital
(50AH)
Operator is Disconnected
o2-07
Motor Direction at Power Up when
(527H)
using Operator
o2-09
Initialization Specification
(50DH)
<1> Parameter setting value is not reset to the default value when the drive is initialized.
n
o3: Copy Function
No. (Addr.)
Name
o3-01
Copy Function Selection
(515H)
o3-02
Copy Allowed Selection
(516H)
n
o4: Maintenance Monitor Settings
No. (Addr.)
Name
o4-01
Cumulative Operation Time
(50BH)
Setting
o4-02
Cumulative Operation Time
(50CH)
Selection
o4-03
Cooling Fan Operation Time
(50EH)
Setting
o4-05
Capacitor Maintenance Setting
(51DH)
o4-07
DC bus Pre-charge Relay
(523H)
Maintenance Setting
o4-09
IGBT Maintenance Setting
(525H)
YASKAWA EUROPE SIEP
All Modes
0: Disabled
1: Enabled. LO/RE key switches between LOCAL and REMOTE operation.
All Modes
0: Disabled. STOP key is disabled in REMOTE operation.
1: Enabled. STOP key is always enabled.
All Modes
0: No change.
1: Set defaults. Saves parameter settings as default values for a User Initialization.
2: Clear all. Clears the default settings that have been saved for a User Initialization.
All Modes
Enter the drive model. Setting required only if installing a new control board.
All Modes
0: ENTER key must be pressed to enter a speed reference.
1: ENTER key is not required. The speed reference can be adjusted using the up and down
arrow keys only.
All Modes
0: The drive continues operating if the digital operator is disconnected.
1: A fault is triggered (oPr) and the motor coasts to stop.
All Modes
0: Forward
1: Reverse
2: European Spec
All Modes
0: No action
1: Read parameters from the drive, saving them onto the digital operator.
2: Copy parameters from the digital operator, writing them to the drive.
3: Verify parameter settings on the drive to check if they match the data saved on the operator.
All Modes
0: Read operation prohibited
1: Read operation allowed
All Modes
Sets the value for the cumulative operation time of the drive in units of 10 h.
All Modes
0: Logs power-on time
1: Logs operation time when the drive output is active (output operation time).
All Modes
Sets the value of the fan operation time monitor U4-03 in units of 10 h.
All Modes
Sets the value of the Maintenance Monitor for the capacitors. See U4-05 to check when the
capacitors may need to be replaced.
All Modes
Sets the value of the Maintenance Monitor for the soft charge bypass relay. See U4-06 to check
when the bypass relay may need to be replaced.
All Modes
Sets the value of the Maintenance Monitor for the IGBTs. See U4-07 to check when the IGBTs
may need to be replaced.
YASKAWA AC Drive L1000V Technical Manual
Description
Description
Description
B.3 Parameter Table
Setting
Page
common_
Default: 0
TMonly
Min: 0
151
Max: 1
common_
Default: 0
TMonly
Min: 0
151
Max: 1
common_
TMonly
Default: 0
Min: 0
151
Max: 2
Default: Determined by
common_
drive capacity
TMonly
152
Min: –
Max: –
common_
TMonly
Default: 0
Min: 0
152
Max: 1
common_
Default: 0
TMonly
Min: 0
152
Max: 1
common_
Default: 0
TMonly
Min: 0
152
Max: 1
Default: 2
Min: 2
Max: 2
Setting
Page
common_
TMonly
Default: 0
Min: 0
153
Max: 3
common_
Default: 0
TMonly
Min: 0
153
Max: 1
Setting
Page
Default: 0 h
common_
TMonly
Min: 0 h
153
Max: 9999 h
common_
Default: 0
TMonly
Min: 0
153
Max: 1
common_
Default: 0 h
TMonly
Min: 0 h
154
Max: 9999 h
common_
Default: 0%
TMonly
Min: 0%
154
Max: 150%
common_
Default: 0%
TMonly
Min: 0%
154
Max: 150%
common_
Default: 0%
TMonly
Min: 0%
154
Max: 150%
B
239