C5-40: ASR Start Speed
Sets the speed level from which the ASR Slip Compensation starts to operate while the Standard Slip Compensation
(C3-
) is shut down. This function is only activated when in simple closed loop control (H6-01=3)
No.
C5-40
u C6: Carrier Frequency
n
C6-02: Carrier Frequency Selection
Sets the carrier frequency for the PWM output.
No.
C6-02
1: 2.0 kHz
2: 5.0 kHz
3: 8.0 kHz
4: 10.0 kHz
5: 12.5 kHz
6: 15.0 kHz
Note:
Refer to Carrier Frequency Derating on page 220
116
P, I
0
Parameter Name
ASR Start Speed
Parameter Name
Carrier Frequency Selection
YASKAWA EUROPE SIEP
P = C5-01
I = C5-02
P = C5-13
I = C5-14
Speed
C5-07
when using a carrier frequency setting above 8.0 kHz.
common
_
Setting Range
0.0 to 100.00 %
Setting Range
1 to 6
YASKAWA AC Drive L1000V Technical Manual
Default
2.50 %
Default
3