4.4 Start-Up Flowcharts

4.4

Start-Up Flowcharts

This section covers basic setup for the drive, including Auto-Tuning procedures and corresponding flowcharts. Refer to
Types of Auto-Tuning on page 80
Flowchart
A
Installation, wiring, and basic steps required to setup the motor and elevator for operation.
B
Auto-Tuning for induction motors.
u Flowchart A: Installation, Wiring, Basic Setup for Motor and Elevator
The flowchart below covers the basic procedure required to install the drive, motor, and elevator.
Figure 4.7
76
for details on the types of Auto-Tuning.
Install the drive as explained in
Mechanical Installation on page
Wire the drive as explained in
Main Circuit Wiring on page
Apply main power to the drive.
Adhere to safety messages concerning application of power.
Check the motor rotation direction.
Select the control mode in parameter A1-02.
Set up the PG encoder in F1-
feedback to the pulse train input RP. Set H6-01 to 3.
Set the Unit Length in parameter o1-12.
Set up o1-20 to o1-22 and then select the display units for speed,
acceleration and deceleration ramp and jerk settings in o1-03.
Perform Auto-Tuning for motor parameters.
Remember that the motor contactor(s) must be closed to perform
this procedure. Perform Rotational Auto-Tuning only if the ropes
are removed.
Set the Speed Reference Selection mode
parameter d1-18
Assign functions to the digital I/O terminals using
parameters H1-
• Preset speed references (d1-
• Acceleration/deceleration ramp (C1-
• Jerk settings (C2-
Set up the Inspection Operation sequence.
Perform a test run.
Fine-tuning
• Adjust settings for the brake sequence (S1-
• Adjust speed control loop (C5-
Figure 4.7 Installation, Wiring, Basic Setup for Motor and Elevator
YASKAWA EUROPE SIEP
Purpose
START
31.
50.
parameters when using single-track
and H2-
Set up:
)
)
)
) .
) etc.
FINISH