B.3 Parameter Table
H2-
Function
Setting
51
Output Contactor Control
54
Light Load Direction
Light Load Direction Detection
55
Status
58
Safe Disable Status
100 to 158
Functions 0 to 58 with Inverse Output
n
H4: Analog Outputs
No.(Addr.)
Name
H4-01
Terminal AM Monitor Selection
(41DH)
H4-02
(41EH)
Terminal AM Gain
H4-03
(41FH)
Terminal AM Bias
n
H6: Pulse Train Input
No.(Addr.)
Name
H6-01
Terminal RP Function Selection
(42CH)
H6-03
(42EH)
Terminal RP Gain
H6-04
(42FH)
Terminal RP Bias
H6-05
(430H)
Pulse Train Input Filter Time
H6-09
PG Pulse Number
(444H)
234
H2 Multi-Function Digital Output Settings
All Modes
Closed: Close output contactor
All Modes
Closed: Light load direction is up
Open: Light load direction is down
All Modes
Closed: Ready for Light Load Direction Search
Open: Light Load Detection in progress
All Modes
Closed: Safe Disable terminals H1-HC and H2-HC are open, drive is in a baseblock state
Open: Safe Disable terminals H1-HC and H2-HC are closed (normal operation)
All Modes
Inverts the output switching of the multi-function output functions.
Sets the last two digits of 1
to reverse the output signal of that specific function.
All Modes
Selects the data to be output through multi-function analog output terminal AM.
Set the desired monitor parameter to the digits available in U -
for U1-03.
All Modes
Sets the signal level at terminal AM that is equal to 100% of the selected monitor value.
All Modes
Sets the signal level at terminal AM that is equal to 0% of the selected monitor value.
All Modes
Selects the function of pulse train input terminal RP.
3: One Channel PG Feedback
F: Not Used
All Modes
Sets the output level when the pulse train input is at 100%, as a percentage of maximum output
frequency..
All Modes
Sets the level of the value selected in H6-01 when a 0 Hz signal is input to terminal RP.
All Modes
Sets the pulse train input filter time constant in seconds.
All Modes
Sets the number of pulses per revolution of the encoder used for feedback.
YASKAWA EUROPE SIEP
Description
Description
. For example, enter "103"
Description
common_
TMonly
common_
TMonly
common_
TMonly
common_
TMonly
common_
TMonly
Setting
common_
TMonly
Default: 102
Min: 000
Max: 999
Default: 100.0%
common_
TMonly
Min: -999.9%
Max: 999.9%
common_
Default: 0.0%
TMonly
Min: -999.9%
Max: 999.9%
Setting
common_
TMonly
Default: F
Min: 3
Max: F
common_
Default: 100.0%
TMonly
Min: 0.0%
Max: 1000.0%
Default: 0.0%
common_
TMonly
Min: -100.0%
Max: 100.0%
Default: 0.10s
common_
TMonly
Min: 0.00s
Max: 2.00s
Default: 1024
common_
TMonly
Min: 500
Max: 10000