Internal/Flush-Mount
An internal flush-mount requires an installation support set that must be purchased separately. Contact a Yaskawa
representative to order an installation support set and mounting hardware.
Support Set A.
Cut an opening in the enclosure panel for the digital operator as shown in Figure 2.9.
1.
Mount the digital operator to the installation support.
2.
Mount the installation support set and digital operator to the enclosure panel.
3.
Figure 2.7
M4 × 10
Phillips truss head screw × 4
(for panel widths between 1 and 1.6)
common_TMonly
Note: Use a gasket between the enclosure panel and the digital operator in environments with a significant amount of dust or other
airborne debris.
Figure 2.8
Figure 2.9 Panel Cut-Out Dimensions (Internal/Flush-Mount Installation)
YASKAWA EUROPE SIEP
Figure 2.8 Internal/Flush Mount Installation
45
+0.5
59
0
YASKAWA AC Drive L1000V Technical Manual
2.2 Mechanical Installation
Figure 2.8
illustrates how to attach Installation
Enclosure panel
Digital Operator
Installation Support Set A
M3 × 6
Phillips recessed
pan head machine screw × 2
Unit: mm