A: Initialization; A: Initialization; A1: Initialization - YASKAWA L1000V Technical Manual

200/400 v classes: 4.0 to 15 kw
Hide thumbs Also See for L1000V:
Table of Contents

Advertisement

5.1 A: Initialization

5.1

A: Initialization

The initialization group contains parameters associated with initial setup of the drive. Parameters involving the display
language, access levels, initialization, and password are located in this group.
u A1: Initialization
n
A1-00: Language Selection
Selects the display language for the digital operator.
Note: 1. This parameter is not reset when the drive is initialized using parameter A1-03.
2. This parameter only affects the language shown on the optional LCD operator JVOP-180.
No.
A1-00
Setting 0: English
Setting 1: Japanese
Setting 2: German
Setting 3: French
Setting 4: Italian
Setting 5: Spanish
Setting 6: Portuguese
Setting 7: Chinese
n
A1-01: Access Level Selection
Allows or restricts access to drive parameters.
No.
A1-01
Setting 0: Operation only
Access is restricted to parameters A1-01, A1-04, and all U monitor parameters.
Setting 1: User Parameters
Access to only a specific list of parameters set to A2-01 through A2-32. These User Parameters can be accessed using the
Setup Mode of the digital operator.
Setting 2: Advanced Access Level (A) and Setup Access Level (S)
All parameters can be viewed and edited.
Notes on Parameter Access
• If the drive parameters are password protected by A1-04 and A1-05, parameters A1-00 through A1-03.
n
A1-02: Control Method Selection
Selects the Control Method (also referred to as the control mode) that the drive uses to operate the motor.
No.
A1-02
Note: This parameter is not reset when the drive is initialized using parameter A1-03.
Setting 0: V/f Control for Induction Motors
Use this mode for simple speed control and for multiple motor applications with low demands to dynamic response or
speed accuracy. This control mode is also used when the motor parameters are unknown and Auto-Tuning cannot be
performed.
102
Parameter Name
Language Selection
Parameter Name
Access Level Selection
Parameter Name
Control Method Selection
YASKAWA EUROPE SIEP
Setting Range
0 to 7
Setting Range
0 to 2
Setting Range
0, 2
YASKAWA AC Drive L1000V Technical Manual
Default
0
Default
2
Default
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents