5.7 H: Terminal Functions
Figure 5.20
Refer to
L4-03, L4-04: Speed Agreement Detection Level and Detection Width (+/-) on page 140
Setting 1A: During down direction
A digital output set for "During down direction" will close whenever the drive is running the elevator in down direction.
Status
Open
Elevator is being driven in up direction or stopped.
Closed
Elevator is being driven in down direction.
Figure 5.21
During Down Direction
Setting 1B: During baseblock (N.C.)
Output opens to indicate that the drive is in a baseblock state. While Baseblock is executed, output transistors do not
switch and no main circuit voltage is output.
Status
Open
Baseblock is being executed.
Closed
Drive is not in a baseblock state.
Setting 1E: Reset enabled
An output set for "Reset enabled" closes when the drive attempts to reset after a fault has occurred.
The fault reset function allows the drive to automatically clear a fault. The terminal set to 1E will close after the fault is
cleared and the drive has attempted to reset. If the drive cannot successfully reset within the number of attempts
permitted by L5-01, a fault will be triggered and the terminal set to 1E will open. Refer to
page 140
for details on automatic reset.
Setting 1F: Motor overload alarm (oL1)
The output closes when the motor overload level estimated by the oL1 fault detection exceeds 90% of the oL1 detection
level.
Setting 20: Drive overheat pre-alarm (oH)
Output closes whenever the drive heatsink temperature reaches the level specified by parameter L8-02. Refer to
Overheat Alarm Level on page 144
132
Output speed
or motor speed
Speed
OFF
ON
detection 4
Figure 5.20 Speed Detection 4 Example with Positive L3-04 Value
Output Speed
Up command
Down command
Figure 5.21 Down Direction Output Example Time Chart
for details on drive overheat detection.
YASKAWA EUROPE SIEP
L4-04
L4-03
Description
ON
OFF
Description
common_
TMonly
for more details.
common_
TMonly
time
L5: Automatic Fault Reset on
YASKAWA AC Drive L1000V Technical Manual
L8-02: