5.7 H: Terminal Functions
Terminal Status
Setting
N.O.
20
O
21
22
O
23
24
O
25
26
O
27
28
O
29
2A
O
2B
2C
O
2D
2E
O
2F
<1> Determines the terminal status for each fault, i.e., whether the terminal is normally open or normally closed.
<2> Determines whether detection for each fault should be enabled only during run or always detected.
Setting 40: Forward Run/Stop
Closing a terminal set for Forward Run/Stop will initiate the drive starting sequence in the forward direction. Opening
the terminal will initiate the drive stopping sequence. This function is set by default to digital input S1. If more than one
digital input is assigned this function an oPE fault will occur.
Setting 41: Reverse Run/Stop
Closing a terminal set for Reverse Run/Stop will initiate the drive starting sequence in the reverse direction. Opening the
terminal will initiate the drive stopping sequence. This function is set by default to digital input S2. If more than one
digital input is assigned this function an oPE fault will occur.
Setting 50: Nominal speed
Closing a terminal set for "Nominal speed" makes the drive run at the speed reference set to d1-19. Conditions change,
however, according to the speed selection mode set in d1-18. Refer to
page 86
for details.
Setting 51: Intermediate speed
Closing a terminal set for "Intermediate speed" makes the drive run at the speed reference set to d1-20. This setting can
also be used in combination with other input terminals set for 50 (Nominal speed) and 52 (Releveling speed) to switch
between the speed reference set in d1-21 and d1-22. Conditions change, however, according to the speed selection mode
set in d1-18. Refer to
Multi-Speed Inputs 1, 2 (d1-18 = 0 or 3) on page
Setting 52: Releveling speed
Closing a terminal set for "Releveling speed" makes the drive run at the speed reference set to d1-23. Conditions change,
however, according to the speed selection mode set in d1-18. Refer to
page 86
for details.
Setting 53: Leveling speed
Closing a terminal set for "Leveling speed" makes the drive run at the speed reference set to d1-26. Conditions change,
however, according to the speed selection mode set in d1-18. Refer to
page 86
for details.
Setting 54: Inspection operation
Causes the drive to operate at the speed reference set in d1-24. To use Inspection Run, this terminal must be close before
the Up or Down command is entered. Refer to
Setting 55: Rescue operation
Initiates Rescue Operation when the terminal closes. Refer to
Setting 56: Motor contactor feedback
Can be used as monitoring input for the motor contactor and allows the drive to detect contactor malfunction.
126
Detection Conditions
<1>
Detected during
N.C.
Always Detected
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
Inspection Operation on page 89
YASKAWA EUROPE SIEP
<2>
Ramp to Stop
Run only
(fault)
O
O
O
O
O
O
O
O
O
O
O
O
Multi-Speed Inputs 1, 2 (d1-18 = 0 or 3) on
86. for details
Multi-Speed Inputs 1, 2 (d1-18 = 0 or 3) on
Multi-Speed Inputs 1, 2 (d1-18 = 0 or 3) on
Rescue Operation on page 91
Stopping Method
Coast to Stop
Emergency Stop
(fault)
(fault)
O
O
O
O
O
O
O
O
for details.
for details.
YASKAWA AC Drive L1000V Technical Manual
Alarm Only