O: Operator Related Settings; O: Operator Related Settings; O1: Digital Operator Display Selection - YASKAWA L1000V Technical Manual

200/400 v classes: 4.0 to 15 kw
Hide thumbs Also See for L1000V:
Table of Contents

Advertisement

5.10 o: Operator Related Settings

5.10 o: Operator Related Settings

These parameters control the various functions, features, and display of the digital operator.
u o1: Digital Operator Display Selection
These parameters determine the data display on the digital operator.
n
o1-01: Drive Mode Unit Monitor Selection
When the drive is powered up, the monitor selected in parameter o1-02 appears first on the display. If o1-02 is set to 5,
o1-01 can be used to change the content of this monitor.
When using an LED operator, pressing the up arrow key will display the following data: speed reference → rotational
direction → output speed → output current → o1-01 selection.
Parameter o1-01 selects the content of the last monitor in this sequence. There is no effect like this on an LCD operator.
No.
o1-01
<1> U2-
and U3-
parameters cannot be selected.
n
o1-02: User Monitor Selection after Power Up
Selects which monitor parameter is displayed upon power up. This is done by entering the 1
monitors are not available in some control modes.
No.
o1-02
Setting 1: Speed reference (U1-01)
Setting 2: Motor direction
Setting 3: Output speed (U1-02)
Setting 4: Output current (U1-03)
Setting 5: User-selected monitor (set by o1-01)
n
o1-03: Digital Operator Display Unit Selection
Sets the units used to display speed related settings and monitors as well as accel/decel rate settings and jerk settings.
Refer to
Digital LCD Operator Display Unit Selection on page
No.
o1-03
Setting 0: 0.01 Hz units
Setting 1: 0.01% units (100% = max. output frequency)
Setting 2: r/min units (calculated by the max output frequency and the no. of motor poles)
Setting 3: User-set units (use o1-10, o1-11)
Set o1-03 to 3 for user-set units, then set parameters o1-10 and o1-11.
Set the value use for the maximum frequency reference to o1-10. The placement of the decimal point in this number
should be set to o1-11.
For example, to have the maximum output speed displayed as "100.00", set the o1-10 = 1000 and o1-11 = 2 (i.e., 1000
with 2 decimal points).
150
Name
Drive Mode Unit Monitor Selection
Refer to U: Monitor Parameters on page 161
Name
User Monitor Selection after Power Up
Name
Digital Operator Display Unit Selection
YASKAWA EUROPE SIEP
Setting Range
105 to 699
U1-04 (Control Mode) to
U6-99 (Option Monitor 20)
Setting Range
1 to 5
78.
Setting Range
0 to 3
YASKAWA AC Drive L1000V Technical Manual
Default
106 (U1-06)
<1>
part of U1-
. Certain
for a list of monitors.
Default
1
Default
0