B.3 Parameter Table
H1-
Function
Setting
20 to 2F
External Fault
40
Forward Run/Stop
41
Reverse Run/Stop
50
Nominal Speed
51
Intermediate Speed
52
Releveling Speed
53
Leveling Speed
54
Inspection Operation
55
Rescue Operation
56
Motor Contactor Feedback
79
Brake Feedback
n
H2: Multi-Function Digital Outputs
No.(Addr.)
Name
H2-01
Terminals MA-MB-MC Function
(40BH)
Selection (relay)
H2-02
Terminals P1-PC Function
(40CH)
Selection (relay)
H2-03
Terminals MD-ME-MF Function
(40DH)
Selection (relay)
H2-
Function
Setting
0
During Run
1
Zero Speed
2
Speed Agree 1
3
User-set Speed Agree 1
232
H1 Multi-Function Digital Input Settings
All Modes
20: N.O., Always detected, ramp to stop
21: N.C., Always detected, ramp to stop
22: N.O., During run, ramp to stop
23: N.C., During run, ramp to stop
24: N.O., Always detected, coast to stop
25: N.C., Always detected, coast to stop
26: N.O., During run, coast to stop
27: N.C., During run, coast to stop
28: N.O., Always detected, Emergency Stop
29: N.C., Always detected, Emergency Stop
2A: N.O., During run, Emergency Stop
2B: N.C., During run, Emergency Stop
2C: N.O., Always detected, alarm only (continue running)
2D: N.C., Always detected, alarm only (continue running)
2E: N.O., During run, alarm only (continue running)
2F: N.C., During run, alarm only (continue running)
All Modes
Closed: Activates Run in the forward direction.
All Modes
Closed: Activates Run in the reverse direction.
All Modes
Closed: Activates the nominal speed (d1-19).
All Modes
Closed: Activates the Intermediate Speed (d1-20).
All Modes
Closed: Activates the Releveling Speed (d1-23).
All Modes
Closed: Activates the Leveling Speed (d1-26).
All Modes
Closed: Activates Inspection operation using the speed set in d1-24.
All Modes
Closed: Activates rescue operation.
All Modes
Used for motor contactor supervision and fault detection.
All Modes
Used for brake supervision and detection of incorrect operation.
All Modes
Refer to
H2 Multi-Function Digital Output Settings on page 232
values.
H2 Multi-Function Digital Output Settings
All Modes
Closed: An Up/Down command is active or voltage is output.
All Modes
Open: Output speed is above the minimum output speed set in E1-09.
Closed: Output speed is below the minimum output speed set in E1-09.
All Modes
Closed: Output speed equals the speed reference (plus or minus the hysteresis set to L4-02).
All Modes
Closed: Output speed and speed reference equal L4-01 (plus or minus the hysteresis set to L4-02).
YASKAWA EUROPE SIEP
Description
Description
for a description of setting
Description
common_
TMonly
common_
TMonly
common_
TMonly
common_
TMonly
common_
TMonly
common_
TMonly
common_
TMonly
common_
TMonly
common_
TMonly
common_
TMonly
common_
TMonly
Setting
Default: E
Min: 0
Max: 158
common_
Default: 6
TMonly
Min: 0
Max: 158
Default: 50
Min: 0
Max: 158
common_
TMonly
common_
TMonly
common_
TMonly
common_
TMonly
YASKAWA AC Drive L1000V Technical Manual
Page
125
126
126
126
126
126
126
126
126
126
127
Page
127
127
127
Page
127
127
128
128