5.4 d: Reference Settings
n
d1-20, d1-21, d1-22: Intermediate Speeds 1 to 3
Sets intermediate speeds 1 through 3.
No.
d1-20
d1-21
d1-22
<1> Setting ranges and defaults vary by the setting units determined by parameter o1-03. Refer to
Selection (o1-03) on page 250
n
d1-23: Releveling Speed
Sets the releveling speed when a multi-function input terminal is programmed for "Releveling speed" (H1-
No.
d1-23
<1> Setting ranges and defaults vary by the setting units determined by parameter o1-03. Refer to
Selection (o1-03) on page 250
n
d1-24: Inspection Operation Speed
Sets the inspection speed when a multi-function input terminal is programmed for "Inspection speed" (H1-
description of the inspection speed can be found in
No.
d1-24
<1> Setting ranges and defaults vary by the setting units determined by parameter o1-03. Refer to
Selection (o1-03) on page 250
n
d1-25: Rescue Operation Speed
Determines the speed during Rescue Operation. Refer to
No.
d1-25
<1> Setting ranges and defaults vary by the setting units determined by parameter o1-03. Refer to
Selection (o1-03) on page 250
n
d1-26: Leveling Speed
Sets the inspection speed when a multi-function input terminal is programmed for "Leveling speed" (H1-
No.
d1-26
<1> Setting ranges and defaults vary by the setting units determined by parameter o1-03. Refer to
Selection (o1-03) on page 250
n
d1-28: Leveling Speed Detection Level
When the speed priority selection in d1-18 is set to "0" or "3" and the speed reference value falls below the level set in
d1-28, the drive interprets the selected speed as leveling speed. This parameter must be set to use the Speed Control Loop
setting 3 when d1-18 = 0/3. Refer to
No.
d1-28
n
d1-29: Inspection Speed Detection Level
When the speed priority selection in d1-18 is set to "0" or "3" and the speed reference value is below the level set in d1-
29 but higher than the level set in d1-28, the drive interprets the selected speed as inspection speed. This parameter must
be set to use the Inspection Operation function when d1-18 = 0/3. Refer to
No.
d1-29
118
Name
Intermediate Speed 1
Intermediate Speed 2
Intermediate Speed 3
for details.
Name
Releveling Speed
for details.
Inspection Operation on page
Name
Inspection Operation Speed
for details.
Name
Rescue Operation Speed
for details.
Name
Leveling Speed
for details.
C5: Speed Control Loop on page 114
Name
Leveling Speed Detection Level
Name
Inspection Speed Detection Level
YASKAWA EUROPE SIEP
Defaults and Setting Ranges by Display Unit
Defaults and Setting Ranges by Display Unit
Defaults and Setting Ranges by Display Unit
Rescue Operation on page 91
Defaults and Setting Ranges by Display Unit
Defaults and Setting Ranges by Display Unit
for details.
Inspection Operation on page 89
Setting Range
0.00 to 120.00 Hz
<1>
0.00 to 120.00 Hz
<1>
0.00 to 120.00 Hz
<1>
Setting Range
0.00 to 120.00 Hz
<1>
89.
Setting Range
0.00 to 120.00 Hz
<1>
for details.
Setting Range
0.00 to 15.00 Hz
<1>
Setting Range
0.00 to 120.00 Hz
<1>
Setting Range
0.00 to 120.00 Hz
Setting Range
0.00 to 120.00 Hz
YASKAWA AC Drive L1000V Technical Manual
Default
0.00 Hz
<1>
0.00 Hz
<1>
0.00 Hz
<1>
= 52).
Default
0.00 Hz
<1>
= 54). A
Default
0.00 Hz
<1>
Default
5.00 Hz
<1>
= 53).
Default
4.00 Hz
<1>
Default
0.00 Hz
for details.
Default
0.00 Hz