B.3 Parameter Table
u d: Speed References
Speed Reference parameters are used to set the various speed reference values during operation.
n
d1: Speed Reference
No.(Addr.)
Name
d1-01
(280H)
Speed Reference 1
d1-02
(281H)
Speed Reference 2
d1-03
(282H)
Speed Reference 3
d1-04
(283H)
Speed Reference 4
d1-05
(284H)
Speed Reference 5
d1-06
(285H)
Speed Reference 6
d1-07
(286H)
Speed Reference 7
d1-08
(287H)
Speed Reference 8
d1-17
(292H)
Jog Speed
d1-18
Speed Reference Selection Mode
(2C0H)
d1-19
(2C1H)
Nominal Speed
d1-20
(2C2H)
Intermediate Speed 1
d1-21
(2C3H)
Intermediate Speed 2
d1-22
(2C4H)
Intermediate Speed 3
d1-23
(2C5H)
Releveling Speed
d1-24
(2C6H)
Inspection Operation Speed
d1-25
(2C7H)
Rescue Operation Speed
228
All Modes
Sets the Speed reference for the drive when d1-18 is set to 0. Setting units are determined by
parameter o1-03.
All Modes
Sets the frequency reference when "Jog Speed" is selected via multi-function digital input
terminals.
All Modes
Sets the mode of speed reference selection by digital inputs.
0: Use multi-speed references (d1-01 to d1-08)
1: High speed reference has priority (d1-19 to d1-23, d1-26)
2: Leveling speed reference has priority (d1-19 to d1-23, d1-26)
All Modes
Sets the nominal speed reference when d1-18 = 1 or 2.
All Modes
Sets intermediate speed reference 1 when d1-18 = 1 or 2.
All Modes
Sets intermediate speed reference 2 when d1-18 = 1 or 2.
All Modes
Sets intermediate speed reference 3 when d1-18 = 1 or 3.
All Modes
Sets speed reference for releveling when d1-18 = 1 or 2.
All Modes
Sets speed reference when inspection operation is enabled.
All Modes
Sets the speed reference during inspection operation.
YASKAWA EUROPE SIEP
Description
Setting
Default: 0.00 Hz
common_
<6>
TMonly
Min: 0.00 Hz
Max: 120.00 Hz
<6> <10>
common_
Default: 6.00 Hz
<6>
TMonly
Min: 0.00 Hz
Max: 120.00 Hz
<6> <10>
common_
TMonly
Default: 1
Min: 0
Max: 2
Default: 50.00 Hz
<6>
common_
Min: 0.00 Hz
TMonly
Max: 120.00 Hz
<6> <10>
common_
TMonly
common_
TMonly
Default: 0.00 Hz
<6>
common_
Min: 0.00 Hz
TMonly
Max: 120.00 Hz
<6> <10>
common_
TMonly
common_
TMonly
Default: 5.00 Hz
<6>
common_
Min: 0.00 Hz
TMonly
Max: 15.00 Hz
<6> <10>