YASKAWA L1000V Technical Manual page 245

200/400 v classes: 4.0 to 15 kw
Hide thumbs Also See for L1000V:
Table of Contents

Advertisement

No. (Addr.)
Name
U2-13
Drive Operation Status at
(8CH)
Previous Fault
U2-14
Cumulative Operation Time at
(8DH)
Previous Fault
U2-15
Soft Starter Output at Previous
(7E0H)
Fault
U2-16
Motor q-Axis Current at
(7E1H)
Previous Fault
U2-17
Motor d-Axis Current at
(7E2H)
Previous Fault
<31> Setting units are determined by the digital operator display unit selection (o1-03).
n
U3: Fault History
No. (Addr.)
Name
U3-01 to
U3-04
First to 4th Most Recent Fault
(90H to 93H)
U3-05 to
U3-10
5th to 10th Most Recent Fault
(804H to
809H)
U3-11 to
Cumulative Operation Time at
U3-14
1st to 4th Most Recent Fault
(94H to 97H)
U3-15 to
U3-20
Cumulative Operation Time at
(80EH to
5th to 10th Most Recent Fault
813H)
n
U4: Maintenance Monitors
No. (Addr.)
Name
U4-01
Cumulative Operation Time
(4CH)
U4-02
Number of Run Commands
(75H)
U4-03
Cooling Fan Operation Time
(67H)
U4-04
Cooling Fan Maintenance
(7EH)
U4-05
Capacitor Maintenance
(7CH)
U4-06
Soft Charge Bypass Relay
(7D6H)
Maintenance
U4-07
IGBT Maintenance
(7D7H)
U4-08
Heatsink Temperature
(68H)
YASKAWA EUROPE SIEP
All Modes
Displays the operation status of the drive at the previous fault. Displays the same status
displayed in U1-12.
All Modes
Displays the cumulative operation time at the previous fault.
All Modes
Displays the speed reference for the soft starter at the previous fault. Displayed in the same way
as U1-16.
V/f
OLV
Displays the q-axis current for the motor at the previous fault. Displayed in the same way as
U6-01.
V/f
OLV
Displays the d-axis current for the motor at the previous fault. Displayed in the same way as
U6-02.
All Modes
Displays the first to the fourth most recent faults.
All Modes
Displays the fifth to the tenth most recent faults.
After ten faults have occurred in the drive, data for the oldest fault is deleted. The most recent
fault appears in U3-01, with the next most recent fault appearing in U3-02. The data is moved to
the next monitor parameter every time a fault occurs.
All Modes
Displays the cumulative operation time when the first to the fourth most recent faults occurred.
All Modes
Displays the cumulative operation time when the fifth to the tenth most recent faults occurred.
All Modes
Displays the cumulative operation time of the drive. The value for the cumulative operation
time counter can be reset in parameter o4-01. Use parameter o4-02 to determine if the operation
time should start as soon as the power is switched on or only while the Up/Down command is
present. The maximum number displayed is 99999, after which the value is reset to 0.
All Modes
Displays the number of run commands that the drive has received. This counter can be reset
using parameter o4-13. The maximum number displayed is 65535, after which the value is reset
to 0.
All Modes
Displays the cumulative operation time of the cooling fan. The default value for the fan
operation time is reset in parameter o4-03. This value will reset to 0 and start counting again
after reaching 99999.
All Modes
Displays main cooling fan usage time in as a percentage of its expected performance life.
Parameter o4-03 can be used to reset this monitor.
All Modes
Displays main circuit capacitor usage time in as a percentage of their expected performance life.
Parameter o4-05 can be used to reset this monitor.
All Modes
Displays the soft charge bypass relay maintenance time as a percentage of its estimated
performance life. Parameter o4-07 can be used to reset this monitor.
All Modes
Displays IGBT usage time as a percentage of the expected performance life. Parameter o4-09
can be used to reset this monitor.
All Modes
Displays the heatsink temperature.
YASKAWA AC Drive L1000V Technical Manual
Description
Description
Description
B.3 Parameter Table
Analog Output
Unit
Level
common_
TMonly
No signal output
available
common_
No signal output
TMonly
1 h
available
common_
TMonly
No signal output
0.01 Hz
available
<31>
common_
TMonly
No signal output
0.10%
available
common_
TMonly
No signal output
0.10%
available
Analog Output
Unit
Level
common_
No signal output
TMonly
available
common_
TMonly
No signal output
available
common_
No signal output
TMonly
1 h
available
common_
No signal output
TMonly
1 h
available
Analog Output
Unit
Level
common_
TMonly
No signal output
1 h
available
common_
TMonly
No signal output
1 h
available
common_
TMonly
No signal output
1 h
available
common_
TMonly
No signal output
1%
available
common_
TMonly
No signal output
1%
available
common_
TMonly
No signal output
1%
available
common_
TMonly
No signal output
1%
available
common_
TMonly
10 V: 100°C
1°C
Page
Page
Page
B
245