No.
H1-07
Terminal S7 Function Selection
H2-01
Terminals MA-MB-MC Function Selection
H2-02
Terminals P1-PC Function Selection
H2-03
Terminal MD-ME-MF Function Selection
H4-01
Terminal AM Monitor Selection
H4-02
Terminal AM Gain
H4-03
Terminal AM Bias
H6-01
Terminal RP Function Selection
H6-03
Terminal RP Gain
H6-04
Terminal RP Bias
H6-05
Pulse Train Input Filter Time
H6-09
PG Pulse Number
L1-01
Motor Overload Protection Selection
L1-02
Motor Overload Protection Time
L1-13
Continuous Electrothermal Operation Selection
L2-05
Undervoltage Detection Level (Uv)
L3-01
Stall Prevention Selection during Acceleration
L3-02
Stall Prevention Level during Acceleration
L3-03
Stall Prevention Limit during Acceleration
L3-05
Stall Prevention Selection during Run
L3-06
Stall Prevention Level during Run
L4-01
Speed Agreement Detection Level
L4-02
Speed Agreement Detection Width
L4-03
Speed Agreement Detection Level (+/-)
L4-04
Speed Agreement Detection Width (+/-)
L5-01
Number of Auto Reset Attempts
L5-02
Fault Output Operation during Auto Reset
L5-04
Fault Reset Interval Time
L5-06
Undervoltage Fault Reset Selection
L6-01
Torque Detection Selection 1
L6-02
Torque Detection Level 1
L6-03
Torque Detection Time 1
L6-04
Torque Detection Selection 2
L6-05
Torque Detection Level 2
L6-06
Torque Detection Time 2
L7-01
Forward Torque Limit
L7-02
Reverse Torque Limit
L7-03
Forward Regenerative Torque Limit
L7-04
Reverse Regenerative Torque Limit
L7-06
Torque Limit Integral Time
L7-07
Torque Limit Control Method during Accel/Decel
L8-02
Overheat Alarm Level
L8-03
Overheat Pre-Alarm Operation Selection
L8-05
Input Phase Loss Protection Selection
L8-07
Output Phase Loss Protection Selection
L8-09
Output Ground Fault Detection Selection
L8-10
Heatsink Cooling Fan Operation Selection
L8-11
Heatsink Cooling Fan Off Delay Time
L8-12
Ambient Temperature Setting
L8-15
oL2 Characteristics Selection at Low Speeds
L8-18
Soft CLA Selection
L8-19
Frequency Reduction Rate during oH Pre-Alarm
L8-35
Installation Selection
L8-38
Automatic Torque Boost Selection
L8-40
Carrier Frequency Reduction Off-Delay Time
L8-41
High Current Alarm Selection
L8-43
Output Phase Loss Detection Time
L8-88
Safe Disable Operation Mode
n2-01
Speed Feedback Detection Control (AFR) Gain
n2-02
Speed Feedback Detection Control (AFR) Time Constant 1
n2-03
Speed Feedback Detection Control (AFR) Time Constant 2
n6-01
Online Tuning Selection
o1-01
Drive Mode Unit Monitor Selection
o1-02
User Monitor Selection After Power Up
o1-03
Digital Operator Display Unit Selection
YASKAWA EUROPE SIEP
User
Name
Setting
YASKAWA AC Drive L1000V Technical Manual
No.
Name
o1-10
User-Set Display Units Maximum Value
o1-11
User-Set Display Units Decimal Display
o2-01
LO/RE Key Function Selection
o2-02
STOP Key Function Selection
o2-03
User Parameter Default Value
o2-04
Drive Model Selection
o2-05
Speed Reference Setting Method Selection
Operation Selection when Digital Operator is
o2-06
Disconnected
o2-07
Motor Direction at Power Up When using Operator
o2-09
Initialization Specification
o3-01
Copy Function Selection
o3-02
Copy Allowed Selection
o4-01
Cumulative Operation Time Setting
o4-02
Cumulative Operation Time Selection
o4-03
Cooling Fan Operation Time Setting
o4-05
Capacitor Maintenance Setting
o4-07
DC Bus Pre-charge Relay Maintenance Setting
o4-09
IGBT Maintenance Setting
o4-11
U2, U3 Initialization
o4-12
kWh Monitor Initialization
o4-13
Number of Travels Counter Reset
S1-01
Zero Speed Level at Stop
S1-02
DC Injection Current at Start
S1-03
DC Injection Current at Stop
S1-04
DC Injection Position Lock Time at Start
S1-05
DC Injection Position Lock Time at Stop
S1-06
Brake Release Delay Time
S1-07
Brake Close Delay Time
S1-10
Run Command Delay Time
S1-11
Output Contactor Open Delay Time
S2-01
Motor Rated Speed
S2-02
Slip Compensation Gain in Motoring Mode
S2-03
Slip Compensation Gain in Regenerative Mode
S2-05
Slip Compensation Torque Detection Delay Time
S2-06
Slip Compensation Torque Detection Filter Time Constant
S4-01
Light Load Direction Search Selection
S4-02
Light Load Direction Search Method
S4-03
Light Load Direction Search Time
S4-04
Light Load Direction Search Speed Reference
S4-05
Rescue Operation Torque Limit
Motor Contactor Response Error (SE1) Detection/Reset
S6-01
Selection
S6-02
Starting Current Error (SE2) Detection Delay Time
S6-04
Output Current Error (SE3) Detection Delay Time
S6-05
Brake Response Error (SE4) Detection Time
S6-15
Speed Reference Loss Detection
S6-16
Restart after Baseblock Selection
S6-20
Rollback Detection Operation Selection
T1-01
Auto-Tuning Mode Selection
T1-02
Motor Rated Power
T1-03
Motor Rated Voltage
T1-04
Motor Rated Current
T1-05
Motor Base Frequency
T1-06
Number of Motor Poles
T1-07
Motor Base Speed
o1-11
User-Set Display Units Decimal Display
o2-01
LO/RE Key Function Selection
o2-02
STOP Key Function Selection
D.3 User Setting Table
User
Setting
271