n
U6: Control Monitors
No. (Addr.)
Name
U6-01
Motor Secondary Current (Iq)
(51H)
U6-02
Motor Excitation Current (Id)
(52H)
U6-03
Speed Control Loop Input
(54H)
U6-04
Speed Control Loop Output
(55H)
U6-05
Output Voltage Reference (Vq)
(59H)
U6-06
Output Voltage Reference (Vd)
(5AH)
U6-07
q-Axis Current Controller
(5FH)
Output
U6-08
d-Axis Current Controller
(60H)
Output
<9> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.
YASKAWA EUROPE SIEP
All Modes
Displays the value of the motor secondary current (Iq). Motor rated secondary current is 100%.
V/f
OLV
Displays the value calculated for the motor excitation current (Id) as a percentage of motor rated
secondary current.
V/f
OLV
Displays the input and output values of the speed control loop.
V/f
OLV
Output voltage reference (Vq) for the q-axis.
V/f
OLV
Output voltage reference (Vd) for the d-axis.
V/f
OLV
Displays the output value for current control relative to motor secondary current (q-axis).
V/f
OLV
Displays the output value for current control relative to motor secondary current (d-axis).
YASKAWA AC Drive L1000V Technical Manual
Description
V/f w PG
B.3 Parameter Table
Analog Output
Unit
Level
10 V: Motor
common_
TMonly
secondary rated
0.1%
current
common_
10 V: Motor
TMonly
secondary rated
0.1%
current
10 V: Max frequency
0.01%
10 V: Motor
secondary rated
current
common_
TMonly
10 V: 200 Vrms
0.1 Vac
<9>
common_
TMonly
10 V: 200 Vrms
0.1 Vac
<9>
common_
TMonly
10 V: 200 Vrms
0.1%
<9>
common_
TMonly
10 V: 200 Vrms
0.1%
<9>