GRAUPNER mz-24 Pro Programming Manual page 52

12 channel hott 2.4 ghz transmitter
Hide thumbs Also See for mz-24 Pro:
Table of Contents

Advertisement

Press the
 WIZ.
button to return to the Pitch Curve
display:
WIZ.
CTL
MIXER
POINT PHASE
Press
SL 1
THR.CRV
3
NONE
NONE
L
NONE
NONE
L
NONE
NONE
L
NONE
NONE
L
NONE
NONE
L
Press the
 WIZ. 
button again to advance to the Throt-
tle Curve display:
WIZ.
NORMAL
PIT.CRV
Pitch min.
FORWARD
Press
Curve
ON
IN
–044%
OUT
+027%
POINT
2
+044%
ST ON
X-axis
Y-axis
52
Base menu - Model selection
THR.CRV
The throttle curve can be specified by assigning up to
7 support points, along the entire control stick travel:
3
THR.Limit
1
INC
1
RES
1
DEC
1
1
Support points can be set, changed and deleted in
the same manner as described in the previous Pitch
Curve section. First specify the throttle curve using
TRIM
three points: the two end points "L" and "H", in addi-
tion to the set point "1" in the control center. These
INC
three points harmonize the motor performance curve
with the pitch curve.
DEC
ENT
Tip
The value shown to the right of the THR.Limit line indi-
cates the status or the position of the throttle limit.
Refer to the FUNCTION submenu THR.CRV section
(page 160) for additional information about setting
throttle curves.
(Throttle Curve)
WIZ.
NORMAL
THR.CRV
OFF
TRIM
Curve
OFF
IN
–100%
INC
OUT
–100%
POINT
L
–100%
DEC
ST OFF
X-axis
Y-axis
ENT
WIZ.
CTL
MIXER
POINT PHASE
SL 1
THR.CRV
3
3
NONE
NONE
L
1
INC
NONE
NONE
L
1
RES
NONE
NONE
L
1
DEC
NONE
NONE
L
1
NONE
NONE
L
1
Notice
The associated controller does not have any ef-
fect if an undefined point is selected (in the basic
version of the relevant curve mixers, only the
points "L" and "H" are set).
Tips
These options and settings directly affect the TRIM
display options found in the FUNCTION submenu
PIT.CRV (page 154).
These options, settings and phase-specific throttle
curve functions can be changed via the FUNCTION
submenu PHASE (page 120).
 WIZ. 
Press the
button again to advance to the Gyro/
Governor display:
Gyr/Gover
Initial basic settings are needed for the gyro and/or
any governor used in the model.
WIZ.
NORMAL
Gyr/Gover
Gyro Suppression
000%
Gyro Gain
000%
Governor ACT
INH
Governor RATE
050%
Tip
These options, settings and phase-specific values can
be changed via the FUNCTION submenu PHASE (page
120).
(Gyro/Governor)
INC
RES
DEC

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents