GRAUPNER mz-24 Pro Programming Manual page 235

12 channel hott 2.4 ghz transmitter
Hide thumbs Also See for mz-24 Pro:
Table of Contents

Advertisement

Graupner HoTT General Engine Module
No. 33610
General sensor for Graupner HoTT receivers and models with gas
engine or electric motor
• 2x temperature and voltage measurements with warning thresh-
olds for min. and max. voltage and min. and max. temperature
• Single cell measurement with warning thresholds for min. volt-
age
• Voltage, current and capacity measurement with warning thresh-
olds for min. and max. voltage, max. capacity and max. current
• Programmable current limiting
• Current limiting with shunt resistors 2 x 1 mOhm parallel = 0.5
mOhm
• Rotational speed measurement and warning thresholds for min.
and max. rotational speed
• Fuel measurement with warning thresholds in 25 % increments
(after software update).
• Settable warning time: OFF, 5, 10, 15, 20, 25, 30 seconds, con-
stant
• Settable repeated warning time: constant, 1, 2, 3, 4, 5 min., once
• 2x temperature selectively 0 to 120°C or 200°C and voltage
measurement up to 80 V DC
• 1x rotational speed measurement up to 100,000 rpm with a two-
blade propeller
• 1x speed controller/servo input, 1x rotational speed regulation
input, 1x speed controller/servo output for rotational speed reg-
ulation
• 1x current and voltage and capacity measurement up to 40 A
(short-term 1 sec 60 A) and up to 30 V
• 1x single cell monitoring for 2 - 6S lithium batteries (LiPo, lithium
ion, LiFe), see
www.graupnerusa.com
for the related items
Graupner HoTT General Air Module
No. 33611
General sensor for Graupner HoTT receivers and models with gas
engine or electric motor
• Vario with altitude signals and ascent and descent signals, and
additional warning thresholds for min. altitude, max. altitude,
rate of ascent and descent in two stages
• Altitude display (-500 to +3000 m) and storage of the min. and
max. altitude.
• 2x temperature and voltage measurements with warning thresh-
olds for min. and max. voltage and min. and max. temperature
• Single cell measurement with warning thresholds for min. volt-
age
• Voltage, current and capacity measurement with warning thresh-
olds for min. and max. voltage, max. capacity and max. current
• Rotational speed measurement with rotational speed regulation
(programmable) and warning thresholds for min. and max. rota-
tional speed
• Fuel measurement with warning thresholds in 25% increments
• Settable warning time: OFF, 5, 10, 15, 20, 25, 30 seconds, con-
stant
• Settable repeated warning time: constant, 1, 2, 3, 4, 5 min., once
• 2x temperature selectively 0 to 120°C or 200°C and voltage
measurement up to 80 V DC
• 1x rotational speed measurement up to 100,000 rpm with a two-
blade propeller
• 1x speed controller/servo input, 1x rotational speed regulation
input, 1x speed controller/servo output for rotational speed reg-
ulation
• 1x current and voltage and capacity measurement up to 40 A
(short-term 1 sec 60 A) and up to 30 V
• etc., see
www.graupnerusa.com
for the related items
Graupner HoTT Electric Air Module
No. 33620
General sensor for Graupner HoTT receivers and models with elec-
tric motor
• Vario with altitude signals and ascent and descent signals, and
additional warning thresholds for min. altitude, max. altitude,
rate of ascent and descent in two stages
• Altitude display (-500 to +3000 m) and storage of the min. and
max. altitude.
• 2x temperature and voltage measurements with warning thresh-
olds for min. and max. voltage and min. and max. temperature
• Single cell measurement 2 - 14 s with warning thresholds for
min. voltage
• Voltage, current and capacity measurement with warning thresh-
olds for min. and max. voltage, max. capacity and max. current
• Settable warning time: OFF, 5, 10, 15, 20, 25, 30 seconds, con-
stant
• Settable repeated warning time: constant, 1, 2, 3, 4, 5 min., once
• 2x temperature selectively 0 to 120°C or 200°C and voltage
measurement up to 80 V DC
• 1x speed controller input, 1x speed controller output for single
cell undervoltage correction
• 1x current and voltage and capacity measurement up to 150 A
(short -term 1 sec 320 A) and up to 60 V
• 1x single cell monitoring for 2 - 14S lithium batteries (LiPo, lith-
ium ion, LiFe)
• 1x Telemetry connection for receiver
Appendix
235

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents