GRAUPNER mz-24 Pro Programming Manual page 109

12 channel hott 2.4 ghz transmitter
Hide thumbs Also See for mz-24 Pro:
Table of Contents

Advertisement

RX SERVO TEST
With the RX SERVO TEST function, you can test the
servos connected to the currently active receiver:
BACK
Telemetry
RX SERVO TEST
V6.35 <
RECV
>ALL-MAX
:
2000µsec
GAM
ALL-MIN
:
1200µsec
TEST
:
STOP
EAM
ALARM VOLT : 3.8V
VARIO
ALARM TEMP+ : 55°C
ALARM TEMP– : –10°C
GPS
CH OUT TYPE : ONCE
ESC
Value
Explanation
V#.##
Receiver firmware
version
ALL-MAX
Servo travel (+plus
side) for all servo out-
puts for the servo test
ALL-MIN
Servo travel (-minus
side) for all servo out-
puts for the servo test
TEST
Test procedure
ALARM
Alarm threshold for the
VOLT
receiver's low voltage
warning
ALARM
Alarm threshold when
TEMP+
the receiver tempera-
ture is too high
ALARM
Alarm threshold when
TEMP–
the receiver tempera-
ture is too low
CH OUT-
Channel sequence
PUT TYPE
or type of aggregate
ESC
symbol
DEC
INC
ALL-MAX
ENT
In this line, set the maximum servo travel on the plus
SET
side of the control travel for the servo test.
2000 μs corresponds to a full deflection on the +plus
side of the servo travel, and 1500 μs corresponds to
Settings
the neutral position.
None
Make sure that the servos do not strike anything
during the test routine.
1500 to
2000 µs
ALL-MIN
In this line, set the maximum servo travel on the -mi-
1500 to
nus side of the control travel for the servo test.
1000 µs
1000 μs corresponds to a full deflection on the -minus
side of the servo travel, and 1500 μs corresponds to
the neutral position.
START / STOP
Make sure that the servos do not strike anything
3.0 to 7.5 V
during the test routine.
default factory
setting: 3.8 V
TEST
50 to 80 °C
Use this line to start and stop the servo test integrat-
default factory
ed in the receiver. Press the
setting: 55 °C
move the bracket to the TEST line, and press the
button at the bottom right of the display. The field
highlights white:
-20 to +10 °C
default factory
setting: -10 °C
ONCE, SAME,
SUMI, SUMO
and SUMD
(Servo Travel +plus Side)
Use the
setting:
(Servo Travel -minus Side)
Press the
return to the main display to start the test. The entry
field returns to normal (yellow):
(Start/Stop)
 INC 
or
 DEC 
button to
 SET 
To stop the servo test, reactivate the entry field as de-
scribed above, choose STOP and confirm by press-
ing the
ALARM VOLT
Through the ALARM VOLT line the operating voltage
of the receiver is monitored. The alarm threshold can
be set between 3.0 and 7.5 Volts in 0.1 Volt incre-
ments.
Base menu - Telemetry | SETTINGS/DISPLAYS
BACK
Telemetry
RECV
RX SERVO TEST
V6.35 <
ESC
ALL-MAX
:
2000µsec
GAM
DEC
ALL-MIN
:
1200µsec
>TEST
:
STOP
EAM
INC
ALARM VOLT
: 3.8V
VARIO
ENT
ALARM TEMP + : 55°C
ALARM TEMP – : –10°C
GPS
SET
CH OUT TYPE : ONCE
ESC
 INC 
or
 DEC 
button to select the START
BACK
Telemetry
RX SERVO TEST
V6.35<
RECV
ESC
ALL-MAX
:
2000µsec
GAM
DEC
ALL-MIN
:
1200µsec
>TEST
:
START
EAM
INC
ALARM VOLT : 3.8V
VARIO
ENT
ALARM TEMP+ : 55°C
ALARM TEMP– : –10°C
GPS
SET
CH OUT TYPE : ONCE
ESC
 SET 
button again to save the selection. To
BACK
Telemetry
RECV
ESC
RX SERVO TEST
V6.35<
ALL-MAX
:
2000µsec
GAM
DEC
ALL-MIN
:
1200µsec
EAM
INC
>TEST
:
START
ALARM VOLT : 3.8V
VARIO
ENT
ALARM TEMP+ : 55°C
ALARM TEMP– : –10°C
GPS
SET
CH OUT TYPE : ONCE
ESC
 SET 
button.
(Receiver Low Voltage Warning)
109