GRAUPNER mz-24 Pro Programming Manual page 122

12 channel hott 2.4 ghz transmitter
Hide thumbs Also See for mz-24 Pro:
Table of Contents

Advertisement

In the example below, the target field was
changed from PHASE 2 to PHASE 4:
BACK
PHASE
SET
PHASE
SLOW
CTL
COPY
1.
NORMAL
0.0s
SOURCE
TARGET
2.
START
0.0s
KEIN
NORMAL
PHASE 4
3.
PHASE 3
YES
NO
4.
PHASE 4
5.
PHASE 5
Press
 NO 
to terminate the procedure. Press
to continue. The source phase information is dupli-
cated to the selected target line:
BACK
SET
PHASE
PHASE
SLOW
CTL
1.
NORMAL
0.0s
2.
START
0.0s
NULL
3.
PHASE 3
4.
PHASE 4
0.0s
NULL
5.
PHASE 5
Change the copied phase line name information by
using the NAM Button (page 121), and/or adapt
the transferred delay or transferred switch as de-
scribed in the SLOW Column section (page 122)
and CTL Column section (page 123).
122 Function menu | general - Phase
•  DEL   Button
The phase information of any phase line highlight-
ed blue can be deleted by pressing the
NEXT
ton at the right of the display. In the example be-
NEW
low, the Phase 4 information needs to be cleared:
NAM
CPY
BACK
DEL
INC
1.
DEC
2.
3.
 YES 
4.
5.
The Phase 4 settings disappear:
NEXT
NEW
BACK
NAM
CPY
1.
DEL
2.
INC
3.
DEC
4.
5.
• SLOW Column
Use this setting to set a delay for a smooth tran-
sition between phases. It is possible to set differ-
ent delays for changing between different phases.
For example, the time delay when moving from a
phase into Phase 3 can differ from when moving
to Phase 1.
(Delete)
 DEL 
but-
PHASE
SET
NEXT
PHASE
SLOW
CTL
NEW
NORMAL
0.0s
NAM
START
0.0s
NULL
CPY
PHASE 3
DEL
INC
PHASE 4
0.0s
NULL
Press
PHASE 5
DEC
PHASE
SET
NEXT
PHASE
SLOW
CTL
NEW
NORMAL
0.0s
NAM
START
0.0s
NULL
CPY
PHASE 3
DEL
INC
PHASE 4
DEC
PHASE 5
(Delay)
To set the delay time, press the field for the appro-
priate phase in the SLOW column:
BACK
PHASE
SET
PHASE
SLOW
CTL
1.
NORMAL
0.0s
2.
START
0.0s
NULL
Press
3.
PHASE 3
4.
PHASE 4
5.
PHASE 5
The field highlights blue:
BACK
PHASE
SET
PHASE
SLOW
CTL
1.
NORMAL
0.0s
2.
START
0.0s
NULL
3.
PHASE 3
4.
PHASE 4
5.
PHASE 5
Raise or lower the value with the
buttons at the right edge. The delay switchover
time can be set anywhere from 0.0 to 9.9 seconds.
In the example below, the NORMAL phase delay is
set for 1.2s:
BACK
SET
PHASE
PHASE
SLOW
CTL
1.
NORMAL
1.2s
2.
START
0.0s
NULL
3.
PHASE 3
4.
PHASE 4
5.
PHASE 5
Use the same procedure with the other phase.
NEXT
NEW
NAM
CPY
DEL
INC
DEC
NEXT
NEW
NAM
CPY
DEL
INC
DEC
INC  
or
 DEL 
NEXT
NEW
NAM
CPY
DEL
INC
DEC