GRAUPNER mz-24 Pro Programming Manual page 195

12 channel hott 2.4 ghz transmitter
Hide thumbs Also See for mz-24 Pro:
Table of Contents

Advertisement

Notice
The  available setting options depend on the
number of ailerons selected during the basic set-
tings of the model (BASE submenu Model Type).
To save and exit, press the
 BACK 
left of the display to return to the previous menu:
BACK
THERMIK
FLAP MIX
FLAP TYP
ACT
SET
CTL
Press
>>
FLAP
AILE >> FLAP
ON
>>
ON
>>
ELEV >> FLAP
INH
ON
INH
>>
ON
FLAP >> ELEV
ELEV >> FLAP line
To support the elevator in tight curves and aerobatics,
the flap function  can be included by controlling the
elevator  with this mixer. Select the mixing direction
so that the flaps move downward when the elevator is
pulled (up), and conversely upward when the elevator
is pushed (down).
A symmetrical or an asymmetrical effect can be de-
fined for each flap pair. Values of ±125% are possible.
The aileron uniform default values are +30%:
BACK
SPEED
Flap MIX
ELEV >> FLAP
CTL
ON
AILE1
AILE3 AILE4
AILE2
RATE A
+030%
+030%
+030%
+030%
+030%
RATE B
+030%
+030%
+030%
The flaps uniform default values are +30%:
ELEV >> FLAP
button at the top
RATE A
RATE B
SERVO
Adapt the individual values as described in the FLAP
Line section (page 192).
Notice
The  available setting options depend on the
number of ailerons selected during the basic set-
tings of the model (BASE submenu Model Type).
To save and exit, press the
left of the display to return to the previous menu:
Press
SERVO
FLAP >> ELEV line
NEXT
When setting flaps, upward or downward torque can
INC
arise about the transverse axis. Elevated flaps also
RES
cause the models to fly faster. These reactions can
DEC
be achieved with the mixer.
When setting the flaps, use this mixer to have the ai-
leron position automatically track the flaps depending
on the set value.
BACK
SERVO
SPEED
Flap MIX
CTL
ON
NEXT
FLAP1
FLAP2
INC
FLAP3 FLAP4
+030%
+030%
+030%
+030%
RES
DEC
+030%
+030%
+030%
+030%
 BACK 
button at the top
BACK
SPEED
Flap MIX
SERVO
FLAP TYPE
ACT
SET
CTL
>>
FLAP
>>
AILE >> FLAP
ON
ON
RUDD >> FLAP
ON
>>
ON
>>
FLAP >> ELEV
INH
ON
The setting can be symmetrical or asymmetrical to the
flap control center point.
The adjustment range is ±125%. This mixers normal
settings lie within the single-digit to low double-digit
range. By default, 0% is uniformly set:
BACK
SPEED
Flap MIX
FLAP >> ELEV
CTL
ELEV1
RATE A
000%
RATE B
000%
Adapt the individual values as described in the FLAP
Line section (page 192).
 BACK 
To save and exit, press the
left of the display to return to the previous menu:
BACK
SPEED
Flap MIX
FLAP TYPE
ACT
SET
Press
>>
FLAP
>>
AILE >> FLAP
ON
ELEV >> FLAP
ON
>>
>>
FLAP >> ELEV
ON
 BACK 
Press the
button at the top left of the display
to return to the FUNCTION menu:
BACK
BASE
FUNCTION
Phase
D/R,EXPO
THR.CRV
Idle LOW
Snap roll
Aile diff
Wing MIX
Flap MIX
Airbrake
TTrainer
Logical sw
Sequence
Function menu | Airplane models - Flaps mixer
SERVO
ON
INC
RES
DEC
button at the top
SERVO
CTL
ON
ON
ON
SYSTEM
Prog.MIX
Flap set
V-Tail
195

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents